What does unknown parameter mean on Siemens UPS?
- KkromeroSep 6, 2025
Attempting to set a parameter that is not known by Siemens DC UPS.
What does unknown parameter mean on Siemens UPS?
Attempting to set a parameter that is not known by Siemens DC UPS.
Why is buffer mode not possible on my Siemens UPS?
If buffer mode is not possible on your Siemens UPS, check settings, cabling, fuse, and battery voltages.
How to fix Siemens UPS device temperature too low?
If the Siemens UPS reports a critically low device temperature, ensure a higher ambient temperature.
Why Siemens UPS input voltage is too high?
Siemens DC UPS is not operational.
Why is the battery not available on my Siemens 6EP4134-3AB00-0AY0 Power Supply?
The Siemens Power Supply is attempting to access a battery that is not available because it was never connected, or communication with this battery was interrupted.
What does EEPROM write error mean on Siemens UPS?
The Siemens UPS device is defective.
What does wrong parameter mean on Siemens UPS?
The parameter value lies outside the valid range on your Siemens UPS.
What does wrong checksum mean on Siemens UPS?
Communication disrupted with your Siemens UPS.
What causes 'Communication error: Wrong length field' on Siemens 6EP4134-3AB00-0AY0 Power Supply?
This error means there's a syntax error in the command sent to the Siemens Power Supply.
What does insufficient charge level mean on Siemens UPS?
The battery charge level is presently too low on your Siemens UPS to reach the set buffer capacity.
Details the DC-UPS modules, their functionality, and key benefits for uninterruptible power.
General safety instructions and warnings for operating electrical devices safely and preventing damage.
Provides detailed descriptions of the SITOP UPS1600 and SITOP UPS1100 units, including their features and functions.
Introduces software tools (STEP 7, UPS Manager, Web server, OPC UA) compatible with SITOP UPS1600.
Details the process for installing and removing the SITOP UPS1600 device, including warnings for hazardous zones.
Explains standard and alternative mounting positions for SITOP UPS1600, including output current derating.
Describes how to connect the 24 V DC supply to the SITOP UPS1600 input terminals.
Presents detailed input voltage and current specifications for SITOP UPS1600 and battery modules.
Covers safety classifications, degree of protection, and test voltages for the SITOP UPS1600.
Details ambient temperature, humidity, pollution degree, and mechanical stress for SITOP UPS1600.
Provides guidelines for product disposal and recycling, emphasizing battery disposal regulations.
Offers contact channels for technical support, including telephone, internet, and documentation resources.
| Product brand name | SITOP |
|---|---|
| Type of supply voltage | AC/DC |
| Output Voltage | 24 V DC |
| Output current | 5 A |
| Output current at rated value V | 5 A |
| Power Rating | 120 W |
| Protection class | Class I |
| Operating temperature | -25 °C to +70 °C |
| Mounting Type | DIN Rail |
| Height | 125 mm |
| Input voltage at AC | 85 ... 264 V |
| Input voltage at DC | 110-300 V DC |