SITOP power supplies
SITOP UPS1600 / UPS1100
Manual
SITOP UPS1600 10 A
6EP4134
-3AB00-0AY0
6EP4134
-3AB00-1AY0
6EP4134
-3AB00-2AY0
SITOP UPS160
0 20 A
6EP4136
-3AB00-0AY0
6EP4136
-3AB00-1AY0
6EP4136
-3AB00-2AY0
SITOP UPS1600 40 A
6EP4137
-3AB00-0AY0
6EP4137
-3AB00-1AY0
6EP4137
-3AB00-2AY0
SITOP UPS1100
Battery module 1.2
Ah
6EP4131
-0GB00-0AY0
Battery module 2.5 Ah
6EP4132
-0GB00-0AY0
Bat
tery module 3.2 Ah
6EP4133
-0GB00-0AY0
Battery module 5 Ah
6EP4133
-0JB00-0AY0
Battery module 7 Ah
6EP4134
-0GB00-0AY0
Battery module 12 Ah
6EP4135-0GB00-0AY0
04.2017
A5E3777
5406-8-76
Overview
Safety instructions
1
Description, device design,
dimension drawing
2
Engineering and remote
access
3
Troubleshooting
4
Mounting/removing
5
Mounting position, mounting
clearances
6
Installation
7
Technical data
8
Safety, approvals, EMC
9
Environmental conditions
10
Environment
11
Service & Support
12

Table of Contents

Other manuals for Siemens 6EP4136-3AB00-0AY0

Questions and Answers

  • M
    mmorganSep 6, 2025
    What does unknown parameter mean on Siemens UPS?
    • D
      Diane JohnsonSep 6, 2025
      Attempting to set a parameter that is not known by Siemens DC UPS.
  • T
    tfieldsAug 25, 2025
    Why is buffer mode not possible on my Siemens UPS?
    • A
      adammirandaAug 25, 2025
      If buffer mode is not possible on your Siemens UPS, check settings, cabling, fuse, and battery voltages.
  • D
    Diane LongAug 25, 2025
    How to fix Siemens UPS device temperature too low?
    • L
      lballAug 26, 2025
      If the Siemens UPS reports a critically low device temperature, ensure a higher ambient temperature.
  • M
    Michelle McdonaldSep 14, 2025
    Why Siemens UPS input voltage is too high?
    • E
      Emily BartonSep 14, 2025
      Siemens DC UPS is not operational.
  • K
    Kelly KingSep 23, 2025
    Why is the battery not available on my Siemens Power Supply?
    • D
      Damon CampbellSep 23, 2025
      The Siemens Power Supply is attempting to access a battery that is not available because it was never connected, or communication with this battery was interrupted.
  • C
    carol51Sep 10, 2025
    What does EEPROM write error mean on Siemens UPS?
    • M
      Mark WashingtonSep 12, 2025
      The Siemens UPS device is defective.
  • A
    Andrea JohnsonSep 2, 2025
    What does wrong parameter mean on Siemens UPS?
    • D
      David HowardSep 2, 2025
      The parameter value lies outside the valid range on your Siemens UPS.
  • C
    christophermullinsSep 2, 2025
    What does wrong checksum mean on Siemens UPS?
    • V
      vstephensonSep 2, 2025
      Communication disrupted with your Siemens UPS.
  • L
    Laura BoydSep 18, 2025
    What causes 'Communication error: Wrong length field' on Siemens 6EP4136-3AB00-0AY0?
    • C
      Christine SmithSep 18, 2025
      This error means there's a syntax error in the command sent to the Siemens Power Supply.
  • J
    Jose CooperAug 28, 2025
    What does insufficient charge level mean on Siemens UPS?
    • P
      Patricia StokesAug 29, 2025
      The battery charge level is presently too low on your Siemens UPS to reach the set buffer capacity.

Summary

Safety instructions

Correct handling of the devices

General safety guidelines for handling electrical devices and preventing hazards.

Description, device design, dimension drawing

Device description

Details on the physical characteristics and functionality of SITOP UPS1600 and SITOP UPS1100 modules.

Connections and terminal designation

Information on terminal layouts and connections for SITOP UPS1600 and SITOP UPS1100 devices.

Operator controls

Explanation of the various controls, switches, and buttons on the SITOP UPS1600 and SITOP UPS1100.

Operating displays and signaling

Description of the LEDs and relay outputs used for device status indication on SITOP UPS1600.

Engineering and remote access

SIMATIC STEP 7 in the TIA Portal

Instructions for using SIMATIC STEP 7 in TIA Portal for SITOP UPS1600 integration and configuration.

SIMATIC STEP 7

Guide for using SIMATIC STEP 7 (non-TIA Portal) for SITOP UPS1600 integration and parameterization.

SITOP UPS Manager

Overview of the SITOP UPS Manager software functions for configuration and monitoring.

Web server

Instructions on accessing and using the web server for monitoring and managing the SITOP UPS1600.

OPC UA server

Information on configuring and using the OPC UA server for data access from SITOP UPS1600.

Troubleshooting

Hardware fault

Guidance on identifying and resolving hardware-related faults and errors in the SITOP UPS1600.

Mounting;removing

SITOP UPS1600

Instructions for the proper mounting and removal of the SITOP UPS1600 device.

Siemens 6EP4136-3AB00-0AY0 Specifications

General IconGeneral
Rated voltage V output24 V DC
Output Current5 A
Output current at rated value5 A
Power rating120 W
Protection classI
Degree of protectionIP20
Input VoltageAC/DC
Input voltage at AC rated value120 ... 230 V
Type of voltage at inputAC
Input voltage range at AC85 ... 264 V AC
Input voltage range at DC110 ... 300 V
Line frequency47 ... 63 Hz
Output Voltage24 V
Operating temperature-25 ... 70 °C
Voltage curve at inputSinusoidal