EasyManua.ls Logo

Siemens 6FC5303-1AF60-8AA0 - Page 29

Siemens 6FC5303-1AF60-8AA0
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Plug X25
Connector designation: X25
Connector type: MCD 1.5/8-G1-3.81 HT BK
Cable length (max.): 1.5 m
Table 3-15 Plug X25
Pin Signal Type Signal name Pin Signal Type Signal name
B1 P24_OUT V Reference pot. +24 V A1 M24_EXT V Reference pot. +24 V
B2 S13 I Emergency stop button A2 HS13 O Emergency stop LED
B3 S14 KT-S14 A3 HS14 LED-S14
B4 S15 KT-S15 A4 HS15 LED-S15
B5 S59 *) KT-IN3/emergency stop override A5 H59 LED-S59
B6 S60 Mode selection A6 H60 LED-S60
B7 S61 Rapid withdrawal A7 H61 LED-S61
B8 S62 *) S32 / HGA enabling unit plug‐
ged in / terminating connector
A8 M24_EXT Reference pot. +24 V
*) can only be used as a neutral input without HGA
Connection for handheld units
You will 󹪝nd a detailed drawing showing the locations of the interfaces in section "Device rear".
Ethernet X1 / X2
Connector designation: X1, X2
Connector type: RJ45 socket
Table 3-16 Ethernet X1 / X2
Pin Signal name Type Meaning
1 TD+
O
Send data +
2 TD- Send data -
3 RD+ I Receive data +
4 N.C. - Not assigned
5 N.C. - Not assigned
6 RD- I Receive data -
7 N.C. - Not assigned
8 N.C. - Not assigned
Note
Only connect the Ethernet interfaces to the LAN, not to telecommunication networks.
Description
3.4 Interfaces
Machine Pushbutton Panel: MPP 464 IE H
Equipment Manual, 03/2021, A5E50810237B AA 29

Table of Contents

Related product manuals