© Siemens AG 2018. All rights reserved
A5E45779389002-01, 09/2018
1
Continuous gas analysis
Field devices of Series 6
Compact Operating Instructions in accordance with
EN 61010-1 and EN 60079-0
Compact Operating Instructions
1
Introduction
1.1
Purpose of this documentation
These instructions are a brief summary of important features, functions and safety information, and contain all necessary
information required for safe use of the respective devices. Read the manual carefully prior to assembly and startup! To
ensure correct handling, become acquainted with the principle of operation of the respective device.
The instructions are aimed at persons who mechanically assemble the devices, connect them electrically, and commission
them.
To achieve optimum usage of the respective device read the detailed version of the respective operating instructions.
1.2
Product versions
These instructions apply to the field devices of Series 6. These include the devices listed below:
ULTRAMAT 6F
OXYMAT 6F
CALOMAT 6F
CALOMAT 62F
These gas analyzers are suitable for a wide variety of measuring tasks and are also available in different versions. The data
on the label, among others, indicates which device version you have.
The label of an OXYMAT 6F is shown below as an example.
1
Data matrix code
2
Disposal information: Do not dispose with household waste!
3
CE conformity symbol
4
Name and address of manufacturer
5
Designation of origin
6
Measuring range(s)
7
Serial number
8
Order No. (MLFB number) of the device
9
Device name

Other manuals for Siemens OXYMAT 6F

Question and Answer IconNeed help?

Do you have a question about the Siemens OXYMAT 6F and is the answer not in the manual?

Siemens OXYMAT 6F Specifications

General IconGeneral
Power supply100 to 240 V AC, 48 to 63 Hz / 24 V DC
Protection classIP40
Response time< 3 s (T90)
Sample gas temperature0 °C to +50 °C
CommunicationRS485 (Modbus RTU)
Measurement principleParamagnetic

Summary

1 Introduction

1.2 Product Versions Overview

Lists the specific field devices of Series 6 covered by these instructions, such as ULTRAMAT 6F and OXYMAT 6F.

1.3 Field of Application Details

Details the approved hazardous area applications for Series 6 field devices, referencing ATEX directives.

1.5 Safety Information and Warnings

Highlights crucial safety information and warnings for device operation, marked with pictograms.

1.7 Qualified Personnel Requirements

Defines the qualifications and responsibilities of personnel handling the devices for safe operation.

2 Safety Instructions

2.1 Precondition for Use

Outlines essential conditions and precautions for safe device operation and maintenance, including symbol explanations.

2.2 Analyzers in Hazardous Areas

Provides safety guidance specific to operating analyzers in hazardous environments, including explosion protection.

3 Assembly and Installation

3.1 General Safety Information

General safety precautions and guidelines for the installation and mounting of the analyzer, covering pressure and media.

3.1.2 Hazardous Area Installation

Specific safety instructions for installing analyzers in hazardous locations, including connection guidelines.

4 Connecting Devices

4.1 Connection Safety Instructions

Safety warnings and precautions for connecting analyzers, including hazardous areas, electrical safety, and grounding.

4.2 Field Device Connections

Details the physical connections for sample gas, reference gas, and purging gas for various field devices.

4.3 Electrical Connections

Provides essential guidelines and torque specifications for electrical connections, including cable glands and wiring.

4.4 Gas Connections

Specifies pipe sizes, materials, and configuration for sample and exhaust gas lines, and gas preparation.

4.5 Hazardous Area Connections

General notes and specific instructions for connecting analyzers in hazardous areas, including flame arrestors and electrical connections.

5 Commissioning Procedures

5.1 Commissioning Safety Instructions

General safety instructions for device commissioning, including hazardous areas, error handling, and enclosure security.

5.2 Containment System Leak Testing

Procedures and test setups for leak testing the analyzer's containment system for CALOMAT and OXYMAT models.

5.3 Hazardous Area Measures

Specific measures required for devices operating in hazardous areas, including Ex px safety equipment, pressure correction, and key switch.

6 Service and Maintenance

6.1 General Safety Instructions

General safety precautions for servicing and maintenance, covering hazardous voltage, media, and electrostatic discharge.

6.2 Hazardous Area Maintenance

Specific maintenance guidelines for analyzers operating in hazardous areas, including Ex px safety equipment and spare parts.

7 Technical Specifications

7.1 General Specifications

General technical data applicable to all analyzer types, including enclosure, electrical, and climatic conditions.

7.6 Hazardous Area Specifications

Technical data specific to hazardous area operation, detailing explosion protection, temperature classes, and electrical data.

8 Disposal and Support

A.1 Service and Support

Contains supplementary information and resources, including technical support contacts and internet resources.