Technical Data  09.02 
14-8  Siemens AG    6SE7087-6AK85-1AA0 
  Rectifier/Regenerating Unit    Operating Instructions 
R/R unit  6SE70..-.....-1AA0  31-4HE85 32-2HE85 32-7HE85 34-2HE85 35-3HE85 
Rated voltage, rated frequency, rated current 
Rated voltage 
Rectifier connection 
Regenerative connection 
 
DC link voltage 
V  
3AC 660V to 690V ±15% 
using an (auto) transformer 
1.2 times the voltage of the rectifier connection 
DC 890V to 930V ±15% 
Rated frequency f
n
 
Input 
Output 
Hz  
46 to 64  (automatic Frequency matching) 
DC 
Rated current 
(rms value) 
With autotransformer
 
 Regenerating, line 
 side 
 Regenerating, unit 
 side 
 Rectifier operation 
Without autotransformer
 
 Regenerating, unit 
 side 
 Rectifier operation 
A  
 
 
136 
 
113 
 
123 
 
113 
 
123 
 
 
 
213 
 
177 
 
193 
 
177 
 
193 
 
 
 
258 
 
215 
 
234 
 
215 
 
234 
 
 
 
404 
 
337 
 
366 
 
337 
 
366 
 
 
 
514 
 
428 
 
465 
 
428 
 
465 
Load class I to EN 60146-1-1 of the DC link current (average value) 
in rectifier operation; currents reduced to 92% in regenerative operation 
Rated current 
(average) 
 Zwischenkreisanschluß 
 beim Einspeisen 
A 140 222 270 420 536 
Load class II to EN 60146-1-1 of the DC link current (average value) 
in rectifier operation; currents reduced to 92% in regenerative operation 
Rated current  A 127 202 246 382 488 
Base load duration  s    240 
Excess current  A 191 303 369 573 732 
Excess current duration  s    60 
Losses, cooling 
Power dissipation 
− 
Maximum 
kW 0,82 1,26 1,15 1,68 1,81 
Cooling air requirement  m
3
/s 0,2 0,2 0,2 0,2 0,2 
Sound pressure level, dimensions, weight 
Sound pressure level dB(A) 75 75 75 75 75 
Size 
Width 
Height 
Depth 
- Standard 
- Option 
 
mm 
mm 
 
mm 
E 
269 
1050 
 
340 
350 
E 
269 
1050 
 
340 
350 
E 
269 
1050 
 
340 
350 
E 
269 
1050 
 
340 
350 
E 
269 
1050 
 
340 
350 
Weight app.  kg  44.5  53.5  53.5  63  68 
 