s
SIMOVERT Master Drives
Rectifier/Regenerating Unit
Sizes C to K
Operating Instructions
Edition: i Order No.: 6SE7087-6AK85-1AA0
https://www.aotewell.com
AoteWell Automation Sales Team
Sales@aotewell.com
AoteWell LTD
Buy Siemens PLC HMI Drives at AoteWell.com
https://www.aotewell.com

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Siemens 6SE7032-4FE85-1AA0 and is the answer not in the manual?

Siemens 6SE7032-4FE85-1AA0 Specifications

General IconGeneral
Product typeDC drive
CoolingForced-air cooling
Communication InterfacePROFIBUS
Input Voltage3-phase, 380-480V AC
Output Voltage0-480V DC

Summary

0 Definitions

DANGER

Indicates an imminently hazardous situation that will result in death or serious injury if not avoided.

WARNING

Indicates a potentially hazardous situation that could result in death or serious injury if not avoided.

CAUTION

Indicates a potentially hazardous situation that may result in minor or moderate injury if not avoided.

2 Transport, Unpacking and Assembly

2.3 Assembly

Lists requirements for securing units of different sizes during assembly.

3 Connection

3.1 Power connections

Details mains and DC link power connections for different unit sizes.

3.2 Power supply and main contactor

Explains connections for auxiliary power supply and main contactor control circuits.

3.3 Control terminal block and serial interface

Covers connections for control terminals and serial interfaces on the CUR module.

3.7 Parallel connection of parallel unit(s), size K

Details how to connect parallel units of size K for increased output current.

3.8 12-pulse mode (only possible with the optional RS485 interface)

Explains the setup and application of 12-pulse mode for harmonic reduction.

4 Start-Up

4.1 Introduction and handling start-up

Provides general information and handling instructions for the start-up procedure.

4.2 Initial start-up

Outlines the preparatory measures and basic steps for initial start-up.

5 Parameter List

5.7 Control

Details parameters for current and voltage control loops, including gains and times.

5.10 Control and status word

Details parameters for configuring control and status words for unit operation.

5.12 Communications

Covers parameters for serial interfaces (SST1, SST2, SCB) and communication protocols.

6 Operator control

6.1 Operator control elements

Describes the functions of the PMU operator control elements like keys and displays.

7 Fault and Alarm Messages

7.1 Fault messages

Details general information on faults, their parameters, and acknowledgment procedures.

8 Maintenance

8.1 Maintenance recommendations

Provides recommendations for fan replacement to ensure unit availability.

8.2 Replacing components

Details procedures for replacing components like fans and modules.

9 Options

10 Spare-parts

14 Technical Data