EasyManua.ls Logo

Siemens 6SE7041-3HK85-1AA0 User Manual

Siemens 6SE7041-3HK85-1AA0
274 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
s
SIMOVERT Master Drives
Rectifier/Regenerating Unit
Sizes C to K
Operating Instructions
Edition: i Order No.: 6SE7087-6AK85-1AA0
https://www.aotewell.com
AoteWell Automation Sales Team
Sales@aotewell.com
AoteWell LTD
Buy Siemens PLC HMI Drives at AoteWell.com
https://www.aotewell.com

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Siemens 6SE7041-3HK85-1AA0 and is the answer not in the manual?

Siemens 6SE7041-3HK85-1AA0 Specifications

General IconGeneral
BrandSiemens
Model6SE7041-3HK85-1AA0
CategoryDC Drives
LanguageEnglish

Summary

Connection

3.1 Power connections

Illustrates mains and DC link power connections for different unit sizes (C, E, H, K).

3.2 Power supply and main contactor

Details the connection of the 24 V DC power supply and main contactor control circuit.

3.3 Control terminal block and serial interface

Explains connections for control terminal blocks and serial interfaces like RS485.

3.6 Power sections

Detailed circuit diagrams of the power sections for different unit sizes.

Start-Up

4.2 Initial start-up

Outlines preparatory measures and the initial start-up procedure.

Parameter List

5.3 General parameters

Covers parameters for language, access level, function selection, and drive settings.

5.4 Drive data

Provides technical data for drive configuration, including rated voltages and currents.

5.5 Hardware configuration

Parameters for configuring installed hardware options.

5.6 Data of the DC link

Details parameters related to the DC link, such as resistance and inductance.

5.7 Control

Parameters for controlling the unit, including current and voltage regulation gains.

5.9 Setpoint channel

Parameters for selecting setpoint sources and handling deviations.

5.10 Control and status word

Parameters for defining sources of control commands and destinations for status signals.

5.12 Communications

Parameters for configuring serial interfaces like SST1, SST2, SCB, CB, and TB.

Operator Control

6.1 Operator control elements

Explains the function of each button on the PMU for controlling the unit.

Fault and Alarm Messages

7.1 Fault messages

Lists fault numbers, their descriptions, possible causes, and countermeasures.

7.2 Alarm messages

Lists alarm numbers, their descriptions, and necessary countermeasures.