Issue 01/06 Function Diagrams
MICROMASTER 440 Parameter List
6SE6400-5BB00-0BP0
281
- 4150 -
Function diagram
87654321
4150_STW1.vsd
Technology Functions
MICROMASTER 440
16.01.2006 V2.1
Control word 1 (r0054)
1)
(1:0)
BI: 1. OFF2
P0844.C
(19:1)
BI: 2. OFF2
P0845.C
(1:0)
BI: Pulse enabling
P0852.C
(1:0)
BI: RFG enable
P1140.C
(1:0)
BI: RFG start
P1141.C
(1:0)
BI:RFG enable setp
P1142.C
1
(722:2)
BI: 1. Faults ackn
P2103.C
(0:0)
BI: 2. Faults ackn
P2104.C
(0:0)
BI: Enable JOG ->
P1055.C
(0:0)
BI: Enable JOG <-
P1056.C
(19:13)
BI: Enable MOP(UP)
P1035.C
(19:14)
BI:Enable MOP(DWN)
P1036.C
(0:0)
BI: CDS b0 loc/rem
P0810
The sequence control is the internal
control (software) for realizing the
inverter status (r0001)
CO/BO: Act CtrlWd1
r0054
r0054
Sequence control 1)
Braking control
Setpoint channel
Sequence control 1)
Braking control
Sequence control 1)
Braking control
Setpoint channel
Sequence control 1)
Sequence control 1)
Setpoint channel
Setpoint channel
Setpoint channel
Sequence control 1)
Setpoint channel
Sequence control 1)
Setpoint channel
Setpoint channel
Setpoint channel
Setpoint channel
Sequence control 1)
Note:This bit must be set in the first PZD word of the
telegram received from serial interfaces,
so that the converter will accept the process data as being
valid (compare USS, PROFIBUS, etc.)
BOP/AOP via "Fn"
1 03 25 47 6
9 8
11 1013 1215 14
Segment Bit
Segment Bit
Seven-segment display
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
0
Bit No.
(722:0)
BI: ON/OFF1
P0840.C
(0:0)
BI:ON reverse/OFF1
P0842.C
1
(1:0)
BI: 1. OFF3
P0848.C
(1:0)
BI: 2. OFF3
P0849.C
(0:0)
BI:ON reverse/OFF1
P0842.C
(722:1)
BI: Reverse
P1113.C
1
All bits = 1 -->
drive runs
Meaning
0 = ON/OFF1, Shutdown via ramp, followed by pulse disable
1 = ON, operating condition (edge-controlled)
0 = OFF2: Electrical stop, pulse disable, motor coasts down
1 = Operating condition
0 = OFF3: Fast stop
1 = Operating condition
Parameter r0054
1 = Pulse enable
0 = Pulse disable
1 = RFG enable
0 = Set RFG to 0
1 = RFG start
0 = Stop RFG
1 = RFG setpoint enable
0 = Setpoint disable
0 = No
1 = Fault acknowledge
0 = NO
1 = JOG right
0 = NO
1 = JOG left
1 = Control from PLC
0 = No control from PLC
1 = Reverse (setpoint inversion)
0 = Revers disabled
reserved
0 = NO
1 = Motor potentiometer MOP up
0 = NO
1 = Motor potentiometer MOP down
0 = NO
1 = CDS Bit 0 (local/remote)
&
&
www . ElectricalPartManuals . com

Table of Contents

Other manuals for Siemens 6SL3352-7AE32-1AA1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens 6SL3352-7AE32-1AA1 and is the answer not in the manual?

Siemens 6SL3352-7AE32-1AA1 Specifications

General IconGeneral
BrandSiemens
Model6SL3352-7AE32-1AA1
CategoryInverter Drive
LanguageEnglish

Related product manuals