Ann.LSAIEC 60870-5-103
FNo. Meaning OpFtNo.CAGIBTTypInf
¨©©©©ª©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©ª©©ª©©ª©©©ª©©ª©©ª©©ª©©©ª©©©
3681Dist.: Fault detection only phase L1 C 1612881
3682Dist.: Fault detection phase L1,E C 1622882
3683Dist.: Fault detection only phase L2 C 1632883
3684Dist.: Fault detection phase L2,E C 1642884
3685Dist.: Fault detection phase L1,2 C 1652885
3686Dist.: Fault detection phase L1,2,E C 1662886
3687Dist.: Fault detection only phase L3 C 1672887
3688Dist.: Fault detection phase L3,E C 1682888
3689Dist.: Fault detection phase L1,3 C 1692889
3690Dist.: Fault detection phase L1,3,E C 1702890
3691Dist.: Fault detection phase L2,3 C 1712891
3692Dist.: Fault detection phase L2,3,E C 1722892
3693Dist.: Fault detection phase L1,2,3 C 1732893
3694Dist.: Fault detection phase L1,2,3,E C 1742894
3719Dist.: Fault det. in forward direction C 149CA BT p 74
3720Dist.: Fault det. in reverse direction C 150CA BT p 75
3771Dist.: Time T1 ( Zone Z1 ) expired C 153CA p78
3774Dist.: Time T2 ( Zone Z2 ) expired C 154CA p79
3777Dist.: Time T3 ( Zone Z3 ) expired C 155CA p80
3778Dist.: Time T4 (direct. zone) expired C 156CAp81
3779Dist.: Time T5 (non-dir. zone) expired C 157CAp82
3780Dist.: Time T1B ( Zone Z1B ) expired C 15828180
3783Dist.: Time T1L ( Zone Z1L ) expired C 15928183
3801Distance protection: General trip C 28201
3802Dist.: Trip phase L1 1pole only C 23828202
3803Dist.: Trip phase L2 1pole only C 23928203
3804Dist.: Trip phase L3 1pole only C 24028204
3805Dist.: Trip 3pole C 241 28205
4014>Dist.:Teleprot./carrier receive POTT C 572914
4024>Dist.:Teleprot./carrier receive PUTT C 582924
4051Dist. teleprotection is switched on CG CAGI p 17
4054Dist. teleprotection: Carrier reception C CAp77
4055Dist. teleprotection: Carrier faulty CG CAGI p 39
4056Dist. teleprotection: Carrier send C CAp76
4062POTT teleprot.:function is switched offCG 63 GI 29 62
4065POTT teleprot.: Carrier faulty CG 60 GI 29 65
4066POTT teleprotection: Carrier send C 2442966
4067POTT teleprotection: Carrier echo send C 592967
4068POTT teleprotection: Transient block C 1982968
4072PUTT teleprot.:function is switched offCG 62 GI 29 72
4075PUTT teleprotection: Carrier faulty CG 61 GI 29 75
4076PUTT teleprotection: Carrier send C 2462976
4164Power swing detection CG 80 GI 29164
4166Out-of-step trip 3pole C 8129166
4221Weak infeed function is switched off CG 112 GI 25 21
4222Weak infeed function is blocked CG GI 25 22
4223Weak infeed function is active CG GI 25 23
4231Weak infeed: General fault detection CG1362531
4241Weak infeed: General trip C 1902541
4242Weak infeed: Trip phase L1 only C 1922542
4243Weak infeed: Trip phase L2 only C 1932543
4244Weak infeed: Trip phase L3 only C 1942544
4245Weak infeed: Trip 3pole C 1952545
4271Switch-onto-fault is switched off CG 118 GI 25 71
4272Switch-onto-fault is blocked CG GI 25 72
4273Switch-onto-fault is active CG GI 25 73
4281Switch-onto-fault: Gen. fault detect. CG2222581