Reyrolle 7SR5
Overcurrent Protection
Device
7SR51
V01.00
Device Manual
C53000-G7040-C014-1
Preface
Open Source Software
Table of Contents
Introduction
1
Basic Structure of the Device Functionality
2
Device Functionality
3
7SR51 Function Templates
4
Protection and Automation Functions
5
Supervision Functions
6
Control Functions
7
Instruments and Meters
8
Functional Tests
9
Technical Data
10
Appendix
A

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Siemens 7SR51 and is the answer not in the manual?

Siemens 7SR51 Specifications

General IconGeneral
BrandSiemens
Model7SR51
CategoryProtection Device
LanguageEnglish

Summary

Reyrolle 7SR5 Overcurrent Protection Device

Preface

Introduction to the manual, including purpose, target audience, and scope.

Open Source Software

Information regarding the use of third-party open-source software included in the product.

Introduction

7SR5 Devices

Identifies the specific relay series covered by this manual.

Basic Structure of the Device Functionality

2.1 Introduction

Overview of the device's functions including protection, supervision, control, and communication.

2.2 Analogue Inputs

Details the device's current (CT) and voltage (VT) input configurations.

2.3 Function Groups and Function Elements

Explains the organization of device functions into groups and elements.

2.4 Device Startup

Describes the device startup process and initial display messages.

2.5 Real Time Clock

Covers time synchronization, setting the time source, and clock behavior.

Device Functionality

3.1 Device Fascia

Details the components of the device fascia, including LCD, buttons, and LEDs.

3.2 Device Configuration

Explains how to configure device parameters, operating modes, and settings.

3.3 CT and VT Inputs

Describes the configuration of current and voltage transformer inputs.

3.4 Binary Inputs

Details the functions, structure, and configuration of binary inputs.

3.5 Binary Outputs

Explains the functions, structure, and configuration of binary outputs.

3.6 Data Storage

Covers demand/data logs, waveform records, fault records, and event logs.

3.7 Data Communications

Describes communication interfaces like USB, RS485, and Ethernet.

3.8 Quick Logic

Explains how to define logic equations for custom control schemes.

7SR51 Function Templates

4.1 Introduction

Overview of function templates, groups, and elements.

4.2 Function Groups and Function Elements

Details the available functions and their typical analogue input requirements.

4.3 Function Configuration

Explains how to enable/disable function groups and elements.

Protection and Automation Functions

5.1 21LB Load Blinder

Functionality and application of load blinders to block overcurrents.

5.2 27 Undervoltage Protection – 3-Phase

Details on 3-phase undervoltage protection, its logic, and settings.

5.4 32 Power Protection

Describes power protection functions for detecting abnormal power levels.

5.11 50 Instantaneous Overcurrent – Phase

Details on instantaneous overcurrent protection for phase faults.

5.17 51 Time-Delayed Overcurrent – Phase

Explains time-delayed overcurrent protection characteristics and settings.

5.25 67 Directional Overcurrent/Earth Fault

Covers directional control for overcurrent and earth fault protection.

5.29 87GH Restricted Earth-Fault Protection – High-Impedance

Details high impedance restricted earth fault protection principles and settings.

Supervision Functions

6.1 50BF Circuit-Breaker Failure Protection – 3 Pole

Monitors circuit breaker status and provides backup trip signal if CB fails.

6.2 60CTS CT Supervision

Detects open circuit CT connections and provides alarms.

6.3 60VTS VT Supervision

Detects loss of voltage supply due to VT fuse operation and provides alarms.

6.4 74CC Close-Circuit Supervision

Monitors integrity of wiring connections for circuit breaker close coils.

6.5 74TC Trip-Circuit Supervision

Monitors integrity of wiring connections for circuit breaker trip coils.

6.6 81HB2 Inrush Current Detection

Detects inrush currents to block mal-operation during transformer switch-in.

Control Functions

7.1 Device Control Functions

Overview of device control capabilities via fascia, menus, and inputs/outputs.

7.2 52 Circuit-Breaker Control

Configuration and monitoring of circuit breaker open/close status and operations.

7.3 79 Automatic Reclosing

Details on setting up autoreclose sequences for various fault types.

Instruments and Meters

8.1 Introduction

Explains how measurands are recorded and displayed.

8.2 Instruments

Lists and describes the various instruments and measured values available.

8.3 Notes

Provides additional notes on instrument measurements and communications.

Functional Tests

9.1 General Notes

General guidelines and precautions for performing functional tests.

9.2 Hardware Measurement Tests

Describes tests for binary inputs, outputs, and analogue measurements.

9.5 Direction Test of the Earth Quantities for Directional Earth-Fault Functions

Procedure for testing directional earth fault elements.

9.6 Circuit‑Breaker Test

Guidance on testing circuit breaker operations and auxiliary contacts.

9.7 Primary and Secondary Tests of the Circuit‑Breaker Failure Protection

Tests for integrating protection functions and circuit breaker failure logic.

9.9 Protection Functional Tests

Details procedures for testing various protection functions.

Technical Data

10.1 General Device Data

Provides typical accuracy and reference values for device measurements.

10.2 21LB Load Blinder

Technical data for 3-phase and single-phase load blinder settings.

10.3 27 Undervoltage Protection – 3-Phase

Technical data for 3-phase undervoltage protection parameters.

10.5 32 Power Protection

Technical data for power protection settings and operating levels.

10.8 46 Negative-Sequence Overcurrent Protection

Technical data for definite and inverse time negative-sequence overcurrent.

10.11 49 Thermal Overload Protection

Technical data for thermal overload protection, including operating times.

10.12 50 Instantaneous Overcurrent – Phase

Technical data for instantaneous overcurrent protection settings.

10.14 50BF Circuit-Breaker Failure Protection – 3 Pole

Technical data for circuit-breaker failure protection parameters.

10.17 50N Instantaneous Earth Fault – Calculated

Technical data for calculated instantaneous earth fault protection.

10.18 51 Time-Delayed Overcurrent – Phase

Technical data for time-delayed overcurrent protection characteristics.

10.23 59 Overvoltage Protection – 3 Phase

Technical data for 3-phase overvoltage protection settings.

10.24 59N Neutral Voltage Displacement

Technical data for neutral voltage displacement protection settings.

10.25 59Vx Overvoltage Protection – Vx

Technical data for single-phase overvoltage protection settings.

10.26 60CTS‑I CT Supervision – Current Reference

Technical data for CT supervision based on current reference.

10.27 60CTS‑V CT Supervision – Voltage Reference

Technical data for CT supervision based on voltage reference.

10.28 60VTS VT Supervision

Technical data for VT supervision parameters.

10.29 67 Directional Overcurrent – Phase

Technical data for directional overcurrent protection settings.

10.34 81 Frequency Protection – "f>" or "f<"

Technical data for frequency protection settings (over/under frequency).

10.37 87GH Restricted Earth-Fault Protection – High-Impedance

Technical data for high-impedance restricted earth-fault protection.

Appendix

A.1 Ordering Information

Product description and order numbers for relays and accessories.

A.2 Current Transformer Connections

Illustrations of typical CT connections.

A.3 Voltage Transformer Connections

Illustrations of typical VT configuration settings and connections.