Reyrolle
Operating 7SR46
V1.00
Manual
C53000-B7040-C103-1
Preface
Open Source Software
Table of Contents
First Steps
1
Installing the Device
2
Handling of the Device
3
Using the Device Fascia
4
Using Reydisp Evolution
5
In Service Operation
6
Commissioning
7
Device Maintenance
8
Security Settings
9
Index

Table of Contents

Other manuals for Siemens Reyrolle 7SR46

Questions and Answers

  • D
    donaldshieldsAug 7, 2025
    What to do if Siemens Reyrolle 7SR46 Protection Device relay does not accept the password?
    • B
      Betty SimsAug 7, 2025
      If your Siemens Protection Device relay does not accept the password, ensure you are entering the correct password. If you have forgotten the correct password, note down the numeric code displayed on the Change Password screen and communicate this code to a Siemens customer care representative to retrieve the password.
  • R
    richmondblakeAug 12, 2025
    How to fix Siemens Reyrolle 7SR46 Protection Device relays not communicating in a ring network?
    • K
      kirkrobertAug 12, 2025
      If your Siemens Protection Device relays aren't communicating in a ring network, verify that all relays are powered up with the auxiliary power supply and have unique addresses. Also, in self-powered mode, check that the CT input current is above 1.62 * I (1-phase) or 0.6 * I (3-phase).
  • J
    Jennifer NealAug 16, 2025
    What to do if Siemens Reyrolle 7SR46 Protection Device relay does not power up?
    • M
      Michael JacksonAug 16, 2025
      If your Siemens Protection Device relay does not power up, check that the correct auxiliary AC or DC voltage is applied with the correct polarity. Ensure that the phase connections are based on the terminal diagram and that CT power is applied. Also, check the USB port if the relay is connected with USB power, and verify the battery healthy voltage if it's powered by battery.
  • B
    Brett RamirezAug 20, 2025
    Why is the HEALTHY LED off or LCD not displaying on my Siemens Reyrolle 7SR46 Protection Device?
    • A
      arichardsAug 20, 2025
      If the HEALTHY LED is off or the LCD is not displaying on your Siemens Protection Device, check the minimum phase currents in the absence of auxiliary voltage. Also, review the error messages and error codes under IRF in the INSTRUMENT MODE.
  • W
    William PottsAug 25, 2025
    Why do binary inputs not work on my Siemens Protection Device?
    • S
      samuelreedAug 26, 2025
      If the binary inputs on your Siemens Protection Device do not work, verify that the correct BI voltage is applied with the correct polarity. Also, check that the binary input settings, such as the pick-up and drop-off timers and the status inversion function, are correctly configured.
  • S
    Stanley TravisAug 28, 2025
    What to do if external trip (ET) input does not work on Siemens Reyrolle 7SR46 Protection Device?
    • N
      Nicole CarterAug 29, 2025
      If the external trip (ET) input on your Siemens Protection Device is not working, check whether the device is operating on CT power or auxiliary power and ensure it is in a healthy condition. Short the ET terminals with a resistance wire and ensure that the line wire resistance is less than or equal to 20 ?.
  • V
    vtorresSep 2, 2025
    How to troubleshoot low/critical battery indication on Siemens Protection Device?
    • N
      Nathan OrtizSep 2, 2025
      If you see a low or critical battery indication on your Siemens Protection Device, check whether the paper strip between the battery clip and battery has been removed. Also, ensure the battery is connected with the correct polarity and verify the battery healthy voltage.

Siemens Reyrolle 7SR46 Specifications

General IconGeneral
BrandSiemens
ModelReyrolle 7SR46
CategoryProtection Device
LanguageEnglish

Related product manuals