SIPROTEC 4
Breaker Management
Device 7VK61
V4.7 and higher
Manual
C53000-G1176-C159-5
Preface
Open Source Software
Table of Contents
Introduction
1
Functions
2
Mounting and Commissioning
3
Technical Data
4
Ordering Information and Accessories
A
Terminal Assignments
B
Connection Examples
C
Default Settings and Protocol-dependent
Functions
D
Functions, Settings, Information
E
Literature
Glossary
Index

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Siemens SIPROTEC 4 7VK61 and is the answer not in the manual?

Siemens SIPROTEC 4 7VK61 Specifications

General IconGeneral
SeriesSIPROTEC 4
Model7VK61
Rated Frequency50/60 Hz
Current Transformer Inputs3
Voltage Transformer Inputs3
Device TypeProtection Relay
Binary InputsUp to 24
Binary Outputs4
Protection FunctionsOvercurrent, Earth Fault
Communication ProtocolsIEC 61850, Modbus
MountingPanel Mount
Operating Temperature-25 °C to +55 °C
StandardsIEC 60255, IEC 61850, IEEE C37.90
InputsBinary inputs
Outputs4

Summary

Introduction

Overall Operation

Describes the SIPROTEC 4 7VK61 relay's system structure, including analog inputs, microcomputer system, and power supply.

Application Scope

Details the 7VK61 relay's multi-purpose use, protective functions, control functions, and communication capabilities.

Device Characteristics

Outlines general features, automatic reclosure, synchronism/voltage check, overcurrent, breaker failure, voltage protection, CFC, command processing, and monitoring functions.

Functions

General Device Functions

Covers device startup, configuration via DIGSI, parameter entry, functional scope, and setting notes for device functions.

Automatic Reclosure Function

Explains the automatic reclosure function, its activation, selectivity, initiation modes, blocking, and various reclosure cycle parameters.

Overcurrent Protection

Details the time overcurrent protection function with four stages, characteristic curves, logic diagrams, and settings for definite and inverse time stages.

Synchronism and Voltage Check

Covers the function to ensure network stability during switching by comparing voltage magnitudes, phase angles, and frequencies.

Under and Over-voltage Protection

Describes protection against undervoltage and overvoltage for phase-to-earth, phase-to-phase, positive sequence, and negative sequence systems.

Circuit Breaker Failure Protection

Explains rapid back-up fault clearance when the circuit breaker fails to respond, including current flow monitoring and auxiliary contact evaluation.

Monitoring Functions

Details hardware and software monitoring, measurement supervision, external transformer circuit checks, and current/voltage symmetry.

Function Control and Circuit Breaker Test

Covers the device's control center, applications like line energization, closure detection, and circuit breaker testing procedures.

Auxiliary Functions

Includes processing of messages, operational measured values, fault record data storage, and statistics.

Command Processing

Describes initiating switching operations, control authorization, command types, sequence in the command path, and interlocking.