Preface
Table of contents
PROFIBUS Communication modules 1
Parameters and properties 2
Data type definitions 3
PROFIBUS-DP - Parameterization in DIGSI 4
Technical data 5
Index

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Siemens SIPROTEC 7VE61 and is the answer not in the manual?

Siemens SIPROTEC 7VE61 Specifications

General IconGeneral
Product TypeProtection relay
Current Input1 A or 5 A
Voltage Inputs4
Number of Measuring InputsUp to 12
Communication InterfacesEthernet, RS485
Operating Temperature-25°C to +55°C
Storage Temperature-40°C to +70°C
Frequency50 Hz, 60 Hz
Binary OutputsUp to 16
Communication ProtocolsIEC 61850, IEC 60870-5-103
MountingRack mounting
DisplayLCD
Protection FunctionsOvercurrent, Earth fault, Overvoltage, Undervoltage, Frequency
StandardsIEC 60255, IEEE C37.90
HousingMetal
Voltage Range80 to 120% of rated voltage

Summary

PROFIBUS Communication Modules

Communication Module Types and Hardware Revisions

Details on available PROFIBUS communication module types and their hardware revisions.

Displaying Module-Specific Information

How to access and interpret module-specific information displayed on the SIPROTEC device.

Parameters and Properties

Bus Specific Parameters

Defines PROFIBUS-DP settings like slave address and PNO identification number.

Fibre-Optical Interface Configuration

Settings for operating mode, redundancy, and network size for fibre-optical connections.

Event List and Configuration Data Settings

Configures event list entries and defines PROFIBUS-DP data for master parameterization.

Switching Operations and Communication Interruption Handling

Details on executing switching operations and handling communication interruptions.

Data Type Definitions

Basic Data Types: Indications and Commands

Defines single-point, single command, double-point, and double command data types.

Measured and Metered Value Data Types

Specifies data formats for measured values (signed integer, float) and metered measurands.

Specialized Data Types: Tap Commands and Event Blocks

Defines data types for transformer tap commands and message blocks for event lists.

PROFIBUS-DP Parameterization in DIGSI

Interface Selection and Mapping Files

Guides on selecting PROFIBUS-DP interface and appropriate mapping files in DIGSI.

Customizing Allocations and Scaling Measured Values

Methods for customizing data object routing and scaling of measured values in DIGSI.

Time Synchronization and STEP7 Integration

Details on time synchronization setup and using SFC14/SFC15 with STEP7.

Technical Data

PSE Module Connection Specifications

Technical data for PROFIBUS connection via the PSE module (RS485 interface).

PSO Module Connection Specifications

Technical data for PROFIBUS connection via the PSO module (fibre-optical interface).