SIPROTEC
Differential Protection
7UT613/63x
V4.60
Manual
C53000-G1176-C160-2
Preface
Introduction 1
Functions 2
Mounting and Commissioning 3
Technical Data 4
Appendix A
Literature
Glossary
Index

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Siemens SIPROTEC 7UT633*-* N series and is the answer not in the manual?

Siemens SIPROTEC 7UT633*-* N series Specifications

General IconGeneral
Rated Current1 A or 5 A
Differential protectionYes
Overcurrent protectionYes
Earth-fault protectionYes
Rated Frequency50 Hz / 60 Hz
Communication InterfacesEthernet
ProtocolsIEC 61850
Operating Temperature-25°C to +55°C
Storage Temperature-40°C to +70°C
Dimensions177 mm
Protection FunctionsDifferential, Overcurrent, Earth-fault, Overvoltage, Undervoltage

Summary

Preface

Introduction

Introduces the SIPROTEC 4 device, its scope of application, properties, and functional scope.

Functions

Describes individual functions available on the SIPROTEC 4 device and their setting possibilities.

Mounting and Commissioning

Provides guidelines for experienced engineers on hardware mounting, connections, and commissioning.

1 Introduction

1.2 Application Scope

Details the device's suitability for protecting transformers, generators, motors, reactors, lines, and busbars.

2 Functions

2.2 Differential Protection

Describes the main protection function based on current comparison, considering transformer ratios and connections.

2.3 Restricted Earth Fault Protection

Explains protection against earth faults by comparing phase and starpoint currents.

2.9 Thermal Overload Protection

Prevents damage due to thermal overloading using thermal replica or hot-spot calculation.

2.11 Overexcitation Protection

Detects increased overflux or overinduction conditions in generators and transformers.

2.12 Reverse Power Protection

Protects turbo-generator units by detecting active power input.

2.17 Circuit Breaker Failure Protection

Provides rapid back-up fault clearance when a circuit breaker fails.

3 Mounting and Commissioning

3.1 Mounting and Connections

Provides guidelines for hardware mounting, connections, and prerequisites for installation.

3.3 Commissioning

Outlines the steps for commissioning the device, including safety warnings and testing procedures.

4 Technical Data

4.2 Differential Protection

Details technical data for differential protection, including pickup values, time delays, and tripping characteristics.

4.3 Restricted earth fault protection

Provides technical data for restricted earth fault protection, including setting ranges, operating time, and frequency influence.

4.9 Thermal Overload

Provides technical data for thermal overload protection, including setting ranges, trip curve, and tolerances.

4.11 Overload Protection

Presents technical data for overload protection, including setting ranges, times, and influencing variables.

4.12 Reverse Power Protection

Provides technical data for reverse power protection, including setting ranges, times, and tolerances.

4.17 Circuit Breaker Failure Protection

Provides technical data for circuit breaker failure protection, including supervision, starting conditions, and times.

A Appendix

A.3 Connection Examples

Shows connection examples for current and voltage transformers for various applications.

A.7 Functional Scope

Lists possible protection functions that can be enabled or disabled based on the device configuration.

A.8 Settings

Provides a comprehensive list of all adjustable parameters for the device's functions.