FNo.Abbreviation Meaning OpFtEIOT
¨©©©©ª©©©©©©©©©©©©©ª©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©ª©©ª©©ª©ª©©©
641Pa[%]= Active power Pa [%] = M
642Pr[%]= Reactive power Pr [%] = M
644f [%]= Frequency f [%] = M
651IL1 = Current in phase IL1 = M
652IL2 = Current in phase IL2 = M
653IL3 = Current in phase IL3 = M
671UL1E= Voltage UL1E = M
672UL2E= Voltage UL2E = M
673UL3E= Voltage UL3E = M
674UL12= Voltage UL12 = M
675UL23= Voltage UL23 = M
676UL31= Voltage UL31 = M
691Pa= Active power Pa = M
692Pr= Reactive power Pr = M
1001TripNo L1= Number of trip commands: Phase L1 M
1002TripNo L2= Number of trip commands: Phase L2 M
1003TripNo L3= Number of trip commands: Phase L3 M
1004ÉIL1/In= Summated current tripped IL1/In M
1005ÉIL2/In= Summated current tripped IL2/In M
1006ÉIL3/In= Summated current tripped IL3/In M
1011AR 1pole= No. of auto-reclose commands:1p RAR M
1012AR 3pole= No. of auto-reclose commands:3p RAR M
1013DAR 3pol= No. of auto-reclose commands:3p DAR M
1106>Start FltLoc>Start fault locator CG IOT
1114Rpri= Fault resistance, Ohm prim. C
1115Xpri= Fault reactance, Ohm prim. C
1117Rsec= Fault resistance, Ohm sec. C
1118Xsec= Fault reactance, Ohm sec. C
1119d = Distance to fault in km C
1120d[%]= Distance to fault in % C
1132FltLoc.inval.Fault location invalid COT
1156>CB Test >CB test start IOT
1174CB in Test Circuit breaker test in progress CG OT
1181CB Test Trip Circuit breaker test: General trip OT
1182CB Test 1pL1 Circuit breaker test: Trip 1pole L1 C OT
1183CB Test 1pL2 Circuit breaker test: Trip 1pole L2 C OT
1184CB Test 1pL3 Circuit breaker test: Trip 1pole L3 C OT
1185CB Test 3p Circuit breaker test: Trip 3pole C OT
1303>E/F block >Block E/F protection IOT
1311>E/F comp. on>Switch on directional E/F comparison IOT
1312>E/F comp.off>Switch off directional E/F comparison IOT
1316>E/F Recept >Carrier reception for direct. E/F compC C IOT
1317>E/F Rec.Fail>Carrier reception for dir. E/F faulty CG IOT
1331E/F Prot. offEarth fault protection is switched off CG OT
1332E/F blocked Earth fault protection is blocked CGCG OT
1333E/F active Earth fault protection is active OT
1334E/F Dir.blockEarth fault prot. direct.stage blocked OT
1341E/F Flt75%Ie>Earth fault detection 75% Ie picked up CG OT
1342E/F Flt Ie<->Earth fault detection non-direct. Ie COT
1343E/F Flt Ie ->Earth fault detection directional Ie COT
1351E/F T-Delay Earth fault protection time expired OT
1352E/F T-> Earth fault prot. dir. time expired OT
1353E/F T<-> Earth fault prot. non-dir. time expired OT
1361E/F Trip Trip by earth fault protection OT
1362E/F Trip L1 Earth fault protection: Trip 1pole L1 COT
1363E/F Trip L2 Earth fault protection: Trip 1pole L2 COT
1364E/F Trip L3 Earth fault protection: Trip 1pole L3 COT
1365E/F Trip 3p Earth fault protection: Trip 3pole COT
1381E/F Dir off Earth fault dir. comp. is switched off CG OT