FNo.Abbreviation Meaning OpFtEIOT
¨©©©©ª©©©©©©©©©©©©©ª©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©ª©©ª©©ª©ª©©©
164U supervisionMeasured value supervision of voltages O
165Failure ÉUp-eFailure: Voltage sum superv. (ph-e) CG OT
166Failure ÉUp-pFailure: Voltage sum superv. (ph-ph) CG OT
167Failure UsymmFailure: Voltage symmetry supervision CG OT
168Failure UmeasFailure: Measuring voltages absent CG OT
169Fuse-Failure Fuse failure monitor operated (>10s) CG OT
170FFM pick-up Fuse failure monitor pick-up CG
171Fail.PhaseSeqFailure: Phase sequence supervision CG OT
203Flt.RecDatDelFault recording data deleted C
204Flt.Rec.viaBIFault recording initiated via bin.inputC
205Flt.Rec.viaKBFault recording initiated via keyboard C
206Flt.Rec.viaPCFault recording initiated via PC interfC
244D Time= Diff. time of clock synchronism M
301Syst.Flt Fault in the power system CGC
302Fault Flt. event w. consecutive no. C
351>CB Aux. L1 >Circuit breaker aux. contact: Phase L1 IOT
352>CB Aux. L2 >Circuit breaker aux. contact: Phase L2 IOT
353>CB Aux. L3 >Circuit breaker aux. contact: Phase L3 IOT
354>CB Aux.3p cl>CB aux. contact:3poles closed (series) IOT
355>CB Aux.1p cl>CB aux. contact:1pole closed(parallel) IOT
356>Manual Close>Manual close IOT
357>CloseCmd.Blo>Block all close commands from externalCG IOT
361>VT mcb Trip >U Line side VT MCB tripped CG IOT
362>V2 mcb Trip >U2 Busbar side VT MCB tripped CG IOT
381>1p Trip Perm>External auto-reclose ready for 1pole CG IOT
382>Only 1pole >External AR programmed for 1pole only CG IOT
383>RAR Release >Release overreach zones RAR CGCG IOT
384>DAR Release >Release overreach zones DAR CGCG IOT
501Device FltDetGeneral fault detection of device OT
502Dev. Drop-offGeneral drop-off of device C
503Dev.FltDet L1General device fault detection: Ph. L1 OT
504Dev.FltDet L2General device fault detection: Ph. L2 OT
505Dev.FltDet L3General device fault detection: Ph. L3 OT
506Dev.FltDet N General device fault detection: Ph. NOT
511Device Trip General trip of device G OT
512Dev.Trip 1pL1General 1pole trip of device: Phase L1 OT
513Dev.Trip 1pL2General 1pole trip of device: Phase L2 OT
514Dev.Trip 1pL3General 1pole trip of device: Phase L3 OT
515Dev.Trip 3p General 3pole trip of device OT
516Dev.Trip forwGeneral trip for fault in forward dir. OT
517Dev.Trip rev.General trip for fault in reverse dir. COT
521IL1/In= Interrupted current: Phase L1(I/In) C
522IL2/In= Interrupted current: Phase L2(I/In) C
523IL3/In= Interrupted current: Phase L3(I/In) C
545T-Drop Time from fault detection to drop-off
546T-Trip Time from fault detection to trip
561Manual Close Circuit breaker manually closed (pulse)C OT
562Man.Close CmdCB close command for manual closing OT
563CB Alarm SuppCB alarm suppressed OT
601IL1[%] = Current in phase IL1 [%] = M
602IL2[%] = Current in phase IL2 [%] = M
603IL3[%] = Current in phase IL3 [%] = M
621UL1E[%]= UL1E [%]= M
622UL2E[%]= UL2E [%]= M
623UL3E[%]= UL3E [%]= M
624UL12[%]= UL12 [%] = M
625UL23[%]= UL23 [%] = M
626UL31[%]= UL31 [%] = M