$SSHQGL[6$
9
&* &
1205 MAN. CLOSE Distance zone effective with manual close
Z1B EFFECTIVE [ ] Z1B directional effective
Z1B DIRECTIONAL [ ] Z1B directional effective
Z1B NON-DIRECT. [ ] Z1B non-directional effective
FD EFFECTIVE [ ] Fault detection
Z1 EFFECTIVE [ ] Z1 effective
1208 SER. COMP Series compensated line
NO []no
YES [ ] yes
1209 PAR. COMP Compensation parallel line
NO []no
YES [ ] yes
1216 RAR -> Z1B Distance zone Z1B effective before 1st RAR
YES [ ] yes
NO []no
1217 DAR BLOCK Effective zone if DAR is blocked
Z1; T1 [ ] Z1; T1
Z1; T1B [ ] Z1; T1B
1218 DAR -> Z1L Distance zone Z1L effective before DAR
YES [ ] yes
NO []no
1220 CLOSE ZONE Distance zone effective for any closure
Z1 EFFECTIVE [ ] Z1 effective
Z1B EFFECTIVE [ ] Z1B effective
FD EFFECTIVE [ ] Fault detection
1221 BLK.AR Z1B Autoreclosure is blocked for Z1B faults
NO []no
WITHIN [ ] Within
OUTSIDE [ ] Outside
1222 BLK.AR Z1L Autoreclosure is blocked for Z1L faults
NO []no
WITHIN [ ] Within
OUTSIDE [ ] Outside
©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©
1300 DIST.PROT. INDEPEND. ZONES
1301 R1 Zone 1: Resistance (phase-phase) R1
min. 0.05 Ï
max. 65.00 ©©©©
1302 X1 Zone 1: Reactance (reach) X1
min. 0.05 Ï
max. 200.00 ©©©©
1303 R1E Zone 1: Resistance (phase-earth) R1E
min. 0.05 Ï
max. 130.00 ©©©©
©©©©©
XS WR ILUPZDUH YHUVLRQ 9
IURP ILUPZDUH YHUVLRQ 9 RU KLJKHU