EasyManua.ls Logo

Siemens 7SG11 Argus - Ordering Information: 7 SG1124 Argus; Directional Four Pole Relay Configuration; Directional Angles and Housing for 7 SG1124

Siemens 7SG11 Argus
22 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Siemens Protection Devices Limited 17
Product description Variants Order No.
Directional O/C relay 7
S
G
1
1
2
-
-
A
0
Ideal for directional overcurrent
| | | | | | | |
and earth fault protection of solid
| | | | | | | |
ring systems utilising the fully Number of elements
| | | | | | | |
independent bi-directional Four pole relay
4
| | | | | | |
feature.
| | | | | | |
Auxiliary supply/binary input voltage
| | | | | | |
24/30/48 V DC auxiliary, 30 V binary input 0 | | | | | |
110/220 V DC auxiliary, 30 V binary input 1 | | | | | |
24/30/48 V DC auxiliary, 48 V binary input 2 | | | | | |
110/220 V DC auxiliary, 48 V binary input 1) 3 | | | | | |
110/220 V DC auxiliary, 110 V low burden binary input 4 | | | | | |
110/220 V DC auxiliary, 220 V low burden binary input 5 | | | | | |
| | | | | |
Type of elements
| | | | | |
3 pole phase-fault directional and sensitive/restricted
earth-fault (SEF/REF)
N
|
|
|
|
|
|
1
|
E
|
3 pole phase-fault directional and earth-fault directional or 3 pole
phase-fault directional and earth-fault
P |
|
|
|
|
|
4
|
E
|
3 pole phase-fault directional and earth-fault directional or 3 pole
phase-fault directional and earth-fault
P |
|
|
|
|
|
5
|
E
|
3 pole phase-fault and earth-fault directional Q
| | | 2 D
3 pole phase-fault and earth-fault directional Q
| | | 3 D
| | | | |
Nominal current
| | | | |
1/ 5 A
A
| | | |
| | | |
I/O range
| | | |
5 Binary Inputs / 11 Binary Outputs (incl. 3 changeover) 1 | | |
9 Binary Inputs / 7 Binary Outputs (incl. 3 changeover) 2 | | |
| | |
Communication interface
| | |
Fibre optic (ST-connector) / IEC 60870-5-103 or Modbus RTU 1 | |
RS485 interface / IEC 60870-5-103 or Modbus RTU 2 | |
| |
Directional measurement characteristic angle (CA)
| |
+30º, +45º for phase faults 1 |
0º, -15º, -45º, -65º for earth faults 2 |
0º, -15º, -45º, -90º for earth faults 3 |
+30º, +45º for phase faults and 0º, -15º, -45º, -65º for earth faults 4 |
+30º, +45º for phase faults and 0º, -15º, -45º, -90º for earth faults 5 |
|
Housing size
|
Case size E6 (4U high)
D
Case size E8 (4U high)
E
1
) High burden 110V & 220V binary inputs compliant with ESI48-4 ESI 1 available via external dropper resistors with 48V binary input version
for 5 binary inputs and 110 V application, order resistor box VCE:2512H10065 in addition
for 9 binary inputs and 110 V application, order resistor box VCE:2512H10064 in addition
for 5 binary inputs and 220 V application, order resistor box VCE:2512H10067 in addition
for 9 binary inputs and 220 V application, order two resistor boxes VCE:2512H10067 in addition
Refer to website for application note about ESI48-4 compliance
Ordering Information – 7SG1124 Argus

Related product manuals