- 3 - 
ADM-Q..12T  motion detector 
The detector detects movement in the 
room under surveillance 
7
 and initiates 
an alarm. It responds most sensitively to 
movement in the directions indicated by 
arrows  
7
B, D. The detector's function is 
based on dual technology (microwave 
and passive infrared). Antimask ensures 
that manipulation close to the detector 
(0.5 meters) is reliably detected. The 
back tamper recognizes if the detector is 
removed with force. 
 
Prerequisites 
The detector should be installed by peo-
ple with specialist knowledge and in 
compliance with valid regulations.  
 
 
The detector is only intended 
for indoor use. Note the posi-
tioning instructions 
6
 . 
 
Opening the detector 
1. Check the scope of delivery 
1
. 
2. Slide up the screw-on cover 
2
A and 
loosen the screw 
2
B. 
3. Pull the housing front 
2
D off the base 
2
C. 
 
Fitting the detector 
1. Fit the mounting base 
2
C as follows: 
-  Define type of fastening 
4
A, B. (also 
refer to mounting bracket option) 
-  Break open three fixing holes. 
-  Break open aperture for cable 
feedthrough 
4
D. 
-  Fit mounting base at the proposed 
height. 
 
 
The mounting base should be 
secured using two screws 
4
A, B and the back tamper 
with one screw 
4
C. 
 
2. Wire the power supply, alarm and 
tamper connections according to the 
options provided by the panel 
8
. 
 
 
Please note the end-of-line 
usage guidelines for simplified 
installation using the end-of-
line (EOL) concept (
5
E,
9
). 
 
3. Fold front 
2
D back onto mounting 
base 
2
C and secure with screw 
2
B. 
Slide down screw-on cover 
2
A. 
 
Programming 
To adjust the settings to the application, 
move the switches into the corresponding 
positions: 
 
 
LED on / off 
5
A 
LED only indicates motion in 
walk test mode. 
LED lights up when detecting 
motion.* 
* factory setting 
 
PIR sensitivity
5
A 
Low sensitivity, for harsh envi-
ronments. 
High sensitivity, for quiet envi-
ronments.* 
* factory setting 
 
Pet immunity 
5
A 
Suppresses alarm for pets up 
to a weight of 30 kg. 
Suppresses alarm for pets up 
to a weight of 12 kg.* 
* factory setting 
 
 
Panel 
5
D must be pressed in 
to suppress pet detection 
5
G. 
For EN 50131-2-4 grade 3 
surveillance, move the panel 
back to its original posi-
tion
5
F. 
 
Microwave sensitivity
5
A 
High sensitivity, for quiet envi-
ronments.* 
Low sensitivity, for harsh envi-
ronments. 
* factory setting 
 
Sensitivity setting 
5
B, 
5
C 
-
*
 
Turn potentiometers 
5
B, 
5
C into the position re-
quired to adjust detector to 
room size and field of vi-
sion. 
5
 B: Passive infrared signal 
5
 C: Microwave signal 
* factory setting is the middle position 
(12-meter field of vision) 
 
Walk test 
Move the LED jumper DIP1 
5
A to ON or 
move the alarm control panel to walk test 
mode.  
Run the walk test for alarm triggering in 
the whole detection area coverage 
7
 of 
the detector. 
Options 
White light filter AO-WL10k 
The white light filter is needed for applica-
tions with extreme white light interference 
(> 4000 lux). 
Loosen the lens currently at the positions 
shown in 
5
F and remove from the detec-
tor. Insert adapter 
3
B into detector and 
press the lens back down. 
 
Wall & ceiling mounting brackets  
10
 
The mounting brackets AZ-MBG3 
10
A 
(ceiling 
10
B and wall 
10
C mounting) can 
be used to swivel the detector ± 45°. Use 
AZ-MBG3 with switch  
10
D for EN grade 3 
installations. 
 
Technical data 
Detection area 
coverage 
wide angle
7
B 
12 m 
Connections  Power supply (2x) 
Alarm (2x) 
Tamper (2x) 
Antimask (2x) 
Supply voltage  9.6 … 16 V
DC
 
(12 V
DC
 nominal) 
Max. ripple  1 V
SS
 
Power consump-
tion 
Max. 34 mA 
Current limit  Max. 0.9 A 
Alarm output  Opens during 
alarm 
Alarm holding time  2 … 3 s 
Tamper contact  Opens during 
alarm 
Antimask Opens during 
alarm after 30 sec. 
Control input  Walk test 
(on: +12V) 
Self test – Fault  Red LED: on 
Trouble relay: open
Warm up period  60 ± 5 s 
Pet immunity   < 12 kg 
< 30 kg 
EMI rejection up to 
2GHz 
> 10 V/m 
Operating tempera-
ture 
-10 °C … +50 °C 
Storage tempera-
ture 
-20 °C … +60 °C 
Air humidity 
EN60721 
< 85 % RH  
not condensing 
Type of housing 
protection 
EN 60529 
EN 50102 
IP41 / IK02 
 
en
 
Instruction  
 
 
en