EasyManua.ls Logo

Siemens SITRANS F M MAG 1100 User Manual

Siemens SITRANS F M MAG 1100
70 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Electromagnetic Flowmeters
SITRANS F M MAG 1100 sensor
Operating Instructions
Electromagnetic flow sensor designed for use with
transmitter types SITRANS F M MAG 5000 / 6000 and
MAG 6000 I
01/2018
A5E03433301-AC
Introduction
1
Safety notes
2
Description
3
Installing/Mounting
4
Connecting
5
Service and maintenance
6
Troubleshooting
7
Technical data
8
Appendix
A
Question and Answer IconNeed help?

Do you have a question about the Siemens SITRANS F M MAG 1100 and is the answer not in the manual?

Siemens SITRANS F M MAG 1100 Specifications

General IconGeneral
Product typeElectromagnetic flowmeter
TypeSITRANS F M MAG 1100
Process pressureUp to 16 bar
Power supply24 V DC
Accuracy±0.5% of measured value
Output signal4 to 20 mA
Process ConnectionFlanged
MaterialStainless steel
Electrode MaterialStainless steel, Hastelloy, Tantalum
Liner MaterialPTFE
Protection ClassIP67
Process temperature-20 to +60 °C

Summary

Safety Notes and Precautions

Compliance with Laws and Directives

Outlines adherence to relevant national and international safety and technical regulations.

Installation in Hazardous Areas

Specifies safety requirements and approvals for installing the device in hazardous locations.

Product Description and Functionality

Installing and Mounting the Flowmeter

Installation Safety Precautions

Highlights critical safety measures and hazards to consider during installation.

Mounting Instructions for MAG 1100/1100 HT

Specific steps and considerations for installing the MAG 1100 and MAG 1100 HT sensors.

Mounting Instructions for MAG 1100 F

Detailed procedures for mounting the MAG 1100 F sensor with clamp connections.

Potential Equalization Methods

Explains the importance and methods for achieving electrical potential equalization.

Connecting the Flowmeter System

General Electrical Installation Safety

Outlines essential safety requirements for electrical connections and installation.

Remote Sensor Installation Procedures

Provides instructions for connecting a remote-mounted sensor to the transmitter.

Troubleshooting Common Issues

Improving Application Accuracy

Steps to resolve issues related to application setup and measurement accuracy.

Sensor Functionality Check

Describes tests to verify the sensor's electrical and mechanical integrity.

Technical Specifications and Data

Related product manuals