Table 8-21 Threaded type SMS 1145
Adapter Sensor L Threaded type
SMS 1145
1)
DN DN Di Do
mm mm mm mm mm
25 25 40 22.6 40.0
38 40 40 35.6 60.0
51 50 40 48.6 70.0
63.5 65 45 60.3 85.0
76 65 45 72.0 98.0
1)
Not suitable for 3A approval
8.12 Certificates and approvals
Table 8-22 Certificates and approvals
Version MAG 1100 MAG 1100 HT MAG 1100 F
Calibration
Standard produc‐
tion calibration,
calibration report
shipped with sen‐
sor
Zero-point, 2 x 25 % and 2 x 90 % Zero-point, 2 x 25 % and 2 x 90 % Zero-point, 2 x 25 % and 2 x 90 %
Conforms to PED - 2014/68/EU and CRN
(PFA)
PED - 2014/68/EU and CRN
(PFA)
PED - 2014/68/EU
Ex approvals
Ceramic
● Ex sensor or
Compact with
MAG 6000 I Ex
ATEX, FM, CSA, IECEx, EAC Ex,
NEPSI
- Zone 1 Ex d e ia IIC T6
- Zone 1 Ex e ia IIC T6
ATEX, FM, CSA, IECEx, EAC Ex
- Zone 1 Ex d e ia IIC T6
- Zone 1 Ex e ia IIC T6
ATEX, EAC Ex
- Zone 1 Ex d e ia IIB T6
ATEX
- Zone 21 Ex tD A21 IP67
Technical data
8.12 Certificates and approvals
SITRANS F M MAG 1100 sensor
62 Operating Instructions, 01/2018, A5E03433301-AC