Company Confidential
Copyright 2003© Siemens AG
Page 13 of 13
Service Repair Documentation
Level 2.5 - C65
Release 1.0
10 Joystick
Fault Symptoms
Customer: GRT:
Joystick malfunction Tbd.
Joystick
Use hot air blower to remove defective component. Avoid excessive heat! Watch surrounding components!
Resolder new component afterwards.
E-commerce order number: L36315-Z77-C218
Soldering temperature: 240 - 255°C
IRIS Diagnose Code: 32100 Keys / Main / No Function
32200 Keys / Main / Reduced Functionality
Joystick Problems
Check the status of the
Joystick visually
okay
not okay
Level 2 Repair
Exchange
Joystick
- check for mechanical
damage
- check for dry joints
Watch for oxidation and
damaged pads of the
Joystick
SCRAP don´t
send back to
WSC
If oxidation
If Joystick repairable