Service Repair Documentation
Level 2.5 - C65
Release 1.0
6 IRDA Diode
Fault Symptoms
Customer: GRT:
IRDA does not work Tbd.
Irda Diode
Use hot air blower to remove defective component. Avoid excessive heat! Watch surrounding components!
Resolder new component afterwards.
E-commerce order number: L36197-F5008-F492
Soldering temperature: 240 - 255°C
IRIS Diagnose Code: 41100 Interfaces / IRDA / No Function
41300 Interfaces / IRDA / Mechanical Damage
IRDA Problems
Check the status of the
IRDA Diode visually
okay
not okay
Level 2 Repair
Exchange
IRDA Diode
not okay
okay
Watch for oxidation and
damaged pads of the IRDA
Diode
- check for dry joints
SCRAP don´t
send back to
WSC