Camera settings
50
Siemens AB
Security Products
05.2014
<Pre-trigger buffer> function allows users to check what happened to cause the
trigger. The <Pre-trigger buffer> frame rate could be pre-determined. On the other
hand, <Post-trigger buffer> is for users to upload certain amount of images after
tampering is triggered.
NOTE: Normally the setting range of the <Pre-trigger buffer> is 1 to 20. However,
the setting range will change accordingly if the frame rate of MJPEG on the <Video
Frame Rate> setting page is 6 or smaller.
Check the box <Continue image upload> to upload the triggered images during
certain time or keep uploading until the trigger is off. Select <Upload for __ sec>
and enter the duration in the blank. The images of the duration will be uploaded to
FTP when tampering is triggered. The setting range is from 1 to 9999 seconds.
Select <Upload during the trigger active> to make the images keep being upload
to FTP during the trigger active until the tampering stops. Set the Image frequency
as the upload frame rate. The setting range is from 1 frame to 15 frames.
NOTE: Make sure FTP configuration has been completed. Refer to FTP for further
details.
Upload Image by E-mail
Select this item and the administrator can assign an E-mail address and configure
various parameters. When tampering is detected, event images will be sent to the
appointed E-mail address.
<Pre-trigger buffer> function allows users to check what happened to cause the
trigger. The <Pre-trigger buffer> frame rate could be pre-determined. On the other
hand, <Post-trigger buffer> is for users to upload certain amount of images after
tampering occurs.
NOTE: Normally the setting range of the <Pre-trigger buffer> is 1 to 20. However,
the setting range will change accordingly if the frame rate of MJPEG on the <Video
Frame Rate> setting page is 6 or smaller.
Check the box <Continue image upload> to upload the triggered images during
certain time or keep uploading until the trigger is off. Select <Upload for __ sec>
and enter the duration in the blank. The images of the duration will be uploading by
E-mail when tampering is triggered. The setting range is from 1 to 9999 seconds.
Select <Upload during the trigger active> to make the images keep being upload
to E-mail during the trigger active until tampering stops. Set the Image frequency
as the upload frame rate. The setting range is from 1 frame to 20 frames.
NOTE: Make sure SMTP configuration has been completed. Refer to Mail for fur-
ther details.