Edge Controller F200 - CFG3.F200
Product Data Sheet
Edge Controller F200 for the cloud integration of FIN Framework, FIN Stack
and/or third-party systems.
2-port Ethernet switch for LAN (includes daisy chaining)
1-port Ethernet for WAN
USB interface for 4G dongles
Operating voltage AC 24 V or DC 24 V
Mounting on standard rails or on the wall
Plug-in screw terminal blocks
Multi-site management
Remote operation and monitoring
Alarm treatment
Remote tool access, update, and configuration via Siemens Cloud Services
Question and Answer IconNeed help?

Do you have a question about the Siemens CFG3.F200 and is the answer not in the manual?

Summary

Functions

Application

Type Summary

Equipment Combinations

Accessories

The accessories listed below are tested but not sold by J2 Innovations, including 4G dongles and power supplies.

Technical and Mechanical Design

LED Indicators

Details on the meaning of different LED states for status, network activity, and operational health of the device.

Notes and Safety

National Safety Regulations

Information regarding national safety regulations and compliance to prevent personal injury and property damage.

Mounting Position and Ambient Temperature

Guidelines for mounting the device and its operational temperature range for optimal performance.

Electric Shock Warning

Warning about electric shock hazards during installation and necessary precautions for safe wiring and placement.

Commissioning; Service

Notice for 4 G Dongle

Important notice regarding rebooting the device after a 4G dongle has been connected for proper setup.

Technical Data

Power Supply Specifications

Details on operating voltage options (AC/DC), functional ground, screw terminals, and internal/external fusing.

Power Consumption

Information on AC and DC power consumption for transformer planning.

Function Data

Details on the device's processor, storage capacity, and data backup capabilities.

Interfaces

Ethernet Interfaces

Specifications for Ethernet ports, including type, bit rate, protocols, cabling, and maximum cable length.

Screw Terminals

Information on screw terminals for wiring, including conductor types, stripping length, screwdriver, and torque.

USB Interface (4 G Internet)

Details on the USB interface for 4G dongles, including plug type, bit rate, maximum load, and cable length.

Conformity and Classification

Ambient Conditions and Protection Classification

Classification details for ambient conditions, protection classification (IP ratings), and environmental compatibility.

Ambient Conditions and Protection Classification

Climatic Ambient Conditions

Specifies storage and operation conditions for temperature and air humidity according to IEC EN standards.

Mechanical Ambient Conditions

Details on mechanical ambient conditions for transport and operation according to IEC EN standards.

Standards, Directives, and Approvals

Product and Family Standards

Lists relevant product standards, family standards, and EMC compliance information.

EU Conformity (CE)

Information regarding EU conformity and where to find the CE declaration for the product.

UL;cUL Approbation (US; Canada)

Details on UL/cUL approbation for US and Canada, including links to relevant databases.

CSA Certification

Information on CSA certification and links to relevant product listing databases.

Environmental Compatibility

Details on the product's environmental compatibility, including RoHS compliance and material assessments.

FCC Statement

Housing and Connection Terminals

Housing Specifications

Details on the housing color, dimensions, and weight of the device.

Connection Terminals Overview

Diagram and description of all connection terminals, including Ethernet, power, and USB interfaces.

Dimensions

Overview

The Siemens J2 Innovations Edge Controller F200 (CFG3.F200) is a compact device designed for the cloud integration of FIN Framework, FIN Stack, and/or third-party systems, primarily for monitoring and controlling buildings. It offers robust connectivity and processing capabilities, making it suitable for various building management applications.

Function Description

The F200 Edge Controller provides two main integration levels: system integration and cloud integration. For system integration, it connects to devices using various protocols such as BACnet (on UDP/IP), Modbus TCP/IP, KNX IP, Haystack over RESTful API, OPC UA, oBix, Sedona, and SQL. This broad protocol support allows for the integration of a wide range of building devices. For cloud integration, the device utilizes Ethernet and 4G connectivity via the MQTT protocol, enabling secure data transmission to the cloud.

The device runs FIN Framework or FIN Stack, providing a platform for monitoring and controlling buildings. It also incorporates FIN Edge2Cloud for secure remote access without the need for a Virtual Private Network (VPN). This feature simplifies remote management and reduces IT overhead. The F200 can securely transmit data to the cloud over both cable networks and mobile networks (e.g., 4G), with support for 4G USB dongles for mobile connectivity.

Important Technical Specifications

  • Connectivity:
    • 2-port Ethernet switch for LAN (10Base-T/100Base-TX, IEEE 802.3 compatible, autosensing 10/100 Mbps), supporting daisy chaining.
    • 1-port Ethernet for WAN (10Base-T/100Base-TX, IEEE 802.3 compatible, autosensing 10/100 Mbps) for internet access.
    • USB 2.0 interface (Type A) for 4G dongles, with a bit rate of 480 Mbit and a maximum load of 500 mA.
    • Cabling: 10 Mbps recommends Min. CAT3 shielded cable; 100 Mbps recommends Min. CAT5 shielded cable. Max cable length is 100 m (330 ft).
  • Power Supply:
    • Operating voltage: AC 24 V (-15/+20%, SELV/PELV or AC 24 V Class 2 (US), 48-63 Hz) or DC 24 V (-15/+20%, SELV/PELV or DC 24 V Class 2 (US)).
    • Power consumption: 16 VA (AC) / 8 W (DC).
    • Internal fusing: 2.5 A irreversible / non-replaceable.
    • External supply line fusing (EU): Non-renewable fuse max. 10 A slow, or circuit breaker max. 13 A (Tripping characteristic B, C, D per EN 60898), or power supply with current limitation of max. 10 A.
    • Functional ground terminal for connection to the building grounding system (PE).
  • Hardware:
    • Processor: NXP i.MX8 DualX.
    • Memory: 2 GB RAM.
    • Storage: 8 GB eMMC.
    • Data backup: Super capacitor to support real-time clock for 7 days in case of power failure.
  • Physical Characteristics:
    • Dimensions: 124 mm (4.88") height, 144 mm (5.67") width, 74.5 mm (2.93") depth (see dimensions diagram for full details).
    • Weight: 350 g (with packaging) / 300 g (without packaging).
    • Color: RAL 7035 (light grey) / RAL 7016 (anthracite grey).
    • Mounting: On standard rails or walls.
    • Degree of protection: IP30 for housing, IP20 for front parts in DIN cut-out and terminal part.
  • Environmental Conditions:
    • Operation temperature: -5 to 50 °C (23 to 122 °F) for horizontal wall mounting; -5 to 45 °C (23 to 113 °F) for vertical wall mounting or horizontal surface.
    • Air humidity: 5-95% (non-condensing).
    • Storage/Transport temperature: -25 to 70 °C (-13 to 158 °F).
    • Classification as per EN 60730: Type 1 automatic action, Class A control function, Degree of pollution 2, Overvoltage category III.
    • Suitable for use in protection class I or II systems.

Usage Features

The F200 Edge Controller is designed for ease of installation and operation. It can be mounted on standard rails or screwed onto a flat surface, offering flexibility in deployment. Plug-in screw terminal blocks are used for power and interface connections (excluding Ethernet), simplifying wiring.

The device includes LED indicators for various activities:

  • Ethernet (Green): Continuously ON for link active, Continuously OFF for no connection, Flashing for network traffic.
  • Ethernet (Yellow): Continuously ON for Link 100 Mbps, Continuously OFF for Link 10 Mbps.
  • RUN (Green): Continuously ON for device operational, Continuously OFF for device not operational, Flashing for start-up or program halted.
  • RUN (Red): Continuously OFF for OK, Continuously ON for HW or SW fault (requires power cycle), Rapid flashing for firmware or application missing/corrupted.
  • SVC (Blue): Continuously ON for connection to the cloud OK, Flashing for no connection to the cloud, onboarding to cloud not finished, or device certificates not updated.

These LEDs provide quick visual feedback on the device's status and connectivity. The device also features a service button for potential diagnostic or maintenance functions.

Maintenance Features

The F200 Edge Controller supports remote operation and monitoring, which is crucial for efficient maintenance. It includes alarm treatment capabilities to notify users of critical events. Remote tool access, updates, and configuration can be performed via Siemens Cloud Services, reducing the need for on-site visits and enabling proactive management.

When using a 4G dongle, it is important to reboot the device after connection. Detailed instructions for 4G dongle setup are provided in the "4G Dongle Commissioning Guide." Users should confirm the compatibility of their chosen 4G dongle with their regional Internet Service Provider's infrastructure, including frequency bands, before ordering.

For safety, national safety regulations must be observed during installation and operation. Adequate ventilation is required to comply with permissible ambient temperatures and prevent overheating, ensuring the longevity of the device. The temperature inside the panel or installation box must be at least 10 K (18° F) lower than the outside temperature. To prevent electric shock, the device must be installed in a lockable cabinet or with terminal covers, and not in locations accessible to children. Conductors must comply with IEC 60332-1-2 and IEC 60332-1-3 or IEC TS 60695-11-21 requirements.

The device is compliant with FCC Part 15 regulations, meaning it will not cause harmful interference and must accept any interference received. Any modifications not expressly approved by Siemens Switzerland Ltd. could void the user's authority to operate the equipment.

Siemens CFG3.F200 Specifications