Technical data of CPU 31xC
6.6 Technical data of the integrated I/O
CPU 31xC and CPU 31x, Technical Data
6-32 Manual, 01/2006 Edition, A5E00105475-06
CPU 313C/314C-2: Pin-out of the integrated AI/AO and DI (connector X11)
3RVLWLRQLQJ
&RQWURO
,QWHUUXSWLQSXW
RXWSXW
6WDQGDUG
&38&RQO\
6WDQGDUG',































$2&K
$2&K
37&K
$,&K
$,&K
$,&K
$,&K
9
,
&
9
,
&
9
,
&
9
,
&
9
9
$
$
3(:[
3(:[
3(:[
3(:[
3(:[
3(:[
3(:[
0
',
',
',
',
',
',
',
',
0
$1$
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;

Table of Contents

Other manuals for Siemens CPU 315-2 DP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens CPU 315-2 DP and is the answer not in the manual?

Siemens CPU 315-2 DP Specifications

General IconGeneral
Memory64 KB
Power Supply24 V DC
Order Number6ES7 315-2AG10-0AB0
Number of DP Masters1
Number of DP Slaves124
Load Memory64 KB
Number of Timers256
Number of Counters256
Data Memory64 KB
Operating Temperature0 to 60 °C
Integrated InterfacesMPI, DP
Digital OutputsNot integrated
Analog InputsNot integrated
Analog OutputsNot integrated
Programming LanguagesLAD, FBD, STL
Digital InputsNot integrated
Weight660 g