FDOOT221, FDOOT241-A3,
FDOOT241-A4, FDOOT241-8,
FDOOT241-9, FDOOT241-A9, FDO241,
FDO221, FDT241, FDT221
Automatic fire detectors
Technical Manual
007004_t_en_--
Building Technologies
2015
-11-04
Control Products and Systems

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Siemens FDOOT221 and is the answer not in the manual?

Siemens FDOOT221 Specifications

General IconGeneral
TypeOptical Smoke Detector
ModelFDOOT221
ColorWhite
Protection ClassIP40
ApprovalsEN 54-7, EN 54-17
Operating Temperature-10°C to +55°C
Storage Temperature-25°C to +70°C
Humidity Range≤ 95 % rel. humidity (non-condensing)

Summary

1 About this document

1.1 Applicable documents

Lists related documents and guidelines for system planning.

2 Safety

2.1 Safety instructions

Essential guidelines for safe installation, operation, and maintenance of the product.

2.2 Safety regulations for the method of operation

Outlines mandatory safety rules for electrical installations and product handling.

3 Structure and function

3.1.1 Detectors with ASAtechnology (S-LINE)

Explains S-LINE detectors, their capabilities, and ASAtechnology features.

3.1.2 Detector with detection algorithms (C-LINE)

Details C-LINE detectors, their reliability, and use of detection algorithms.

3.5 Function

Explains how parameter sets influence detector behavior and how to select them.

4 Planning

4.1 Compatibility

Outlines compatibility of neural fire detectors with different control panels and detector lines.

4.3 Parameter sets: Neural fire detector

Details parameter sets for neural fire detectors in sensor mode 0 (neural fire detection).

4.3.4 Neural fire detector FDOOT221

Explains the parameter sets 'Standard' and 'Standard Plus' for the FDOOT221 detector.

4.4 Parameter sets: Wide-spectrum smoke detector

Describes parameter sets for the FDO241 and FDO221 wide-spectrum smoke detectors.

4.5 Parameter sets: Heat detector

Details parameter sets for the FDT241 and FDT221 heat detectors.

4.6 Default settings

Lists default parameter sets for various detector types when not explicitly configured.

5 Mounting Installation

5.4 Preparing detector base FDB22 x for installing an FDOOT241-A3 or FDOOT241-A4

Guides on preparing detector bases for replacing older detector types.

5.19 Detector lines

Explains general cabling information and connection diagrams for various detector lines.

5.19.1 Connection diagram for FDnet detector line

Shows connection diagrams for FDnet detector lines, including loops and branches.

6 Commissioning

Commissioning FDnet, AnalogPLUS, interactive, and SIGMALOOP

Explains the process of commissioning detectors via the control panel.

Commissioning a collective or MS8 detector line

Details the commissioning process for collective and MS8 detector lines.

7 Maintenance Repair

7.1 Status polling with the detector exchanger and tester

Describes how to read device data and perform tests using service tools.

7.2 Performance check

Explains the importance of regular performance checks and the tools used for them.

7.3 Testing detectors

Lists appropriate accessories and tools for testing various detector types.

7.3.1 Testing detectors with detector exchanger and tester

Guides on testing detectors using exchanger and tester, including test mode duration.

7.3.2 Testing detectors without detector exchanger and testerdetector tester

Explains testing methods without specialized service tools, considering detector resistance to phenomena.

8 Specifications

8.1 Technical data FDOOT221, FDOOT241-x -Ax

Provides comprehensive technical specifications for FDOOT221 and FDOOT241-x/-Ax detectors.

8.2 Technical data FDO221, FDO241

Comprehensive technical specifications for FDO221 and FDO241 detectors.

8.3 Technical data FDT221, FDT241

Comprehensive technical specifications for FDT221 and FDT241 detectors.