Do you have a question about the Siemens FC700A and is the answer not in the manual?
Brand | Siemens |
---|---|
Model | FC700A |
Category | Fire Alarms |
Language | English |
Describes the function of hardware modules for the FC700A control unit.
Contains information for all FC700A modules, valid for all software versions.
Identifies intended users: Project Manager, Installation, Commissioning, Product Specialist.
Lists related documents and their numbers for further information.
Personnel must read and understand operating instructions, especially safety regulations.
Siemens disclaims liability for damage from incorrect use or disregard of safety instructions.
Explains symbols and abbreviations used in the document.
Details information on title/last pages and version history for document tracking.
Defines danger levels using signal words and illustrates danger symbols.
Explains the meaning and consequences of DANGER, WARNING, CAUTION, and NOTE.
Explains symbols for tips/information and critical decisions.
Outlines country-specific standards and electrical installation safety rules.
Covers safety precautions for testing and guidelines for system modifications.
Guidelines for using compatible modules, spare parts, and fuses.
Overview of the CPU module (B3Q700) and its connections.
Overview of Line modules (E3M080, E3M111) and their function.
Overview of the LON module (E3I040).
Overview of various control modules (E3L020, E3G050, E3G060, E3G070, Z3B171).
Lists peripheral equipment like FÜ, FBF, FSD, ÜE and their specifications.
Diagrams showing connections for Control terminal, Repeater panel, Printer, Gateway, Power supply.
Lists modules related to Control terminals, Printer, Gateway, and Power supply.
Explains alarm display during failure across C-Bus and I-Bus.
Describes emergency operation at E3M111 and E3M080 line module levels.
System must have EN54 compliant console and emergency power supply.
Illustrates wiring for emergency operation circuits and power supply.
Table detailing wire count based on application requirements for 24V and emergency power supply.
Diagram showing standard 24V power supply connections to FC700A.
Illustrates cascading principle for standard and auxiliary power supplies.
Lists modules suitable for FM installations and their jumper settings.
Notes on FM compliance with E3L030 and verification of module/jumper settings.
Explains programming ground fault monitoring for C-Bus and LON-Bus networks.
Describes the E3C011 module for battery charging and monitoring.
Lists technical specifications like input voltage, battery type, and charging characteristics.
Identifies key components of the E3C011 module, including fuses and switches.
Table for setting battery type using switch S2.
Instructions for setting the I-Bus address using switch S3.
Graphs showing voltage vs. temperature for different battery types.
Explains the meaning of LEDs on the battery-charger indicator block.
Shows terminal block and plug-in connections for the E3C011 module.
Describes the B2F020 converter and lists its technical specifications.
Identifies key components of the B2F020 converter, including jumpers and mounting.
Shows mains and output connections for the B2F020 converter.
Discusses limits for B2F020 as standard or auxiliary power supply.
Describes the E3M080 and lists its technical data.
Shows line voltage ranges for alarm, leak, quiescent, and open line states.
Identifies termination elements and detector compatibility.
Identifies fuses, switches, and connectors; provides S3 programming.
Shows terminal block and plug-in connections for the E3M080 module.
Wiring diagrams for connecting collective detectors to SynoLINE600/-Ex.
Describes E3M111, lists technical data, and explains line separator function.
Identifies fuses, switches, and connectors; provides S3 programming.
Shows terminal block and plug-in connections for the E3M111 module.
Wiring diagrams for connecting addressable SynoLOOP detectors.
Wiring diagrams for connecting conventional SynoLINE300 detectors.
Wiring diagrams for connecting collective SynoLINE600 detectors.
Wiring diagrams for collective SynoLINE600-Ex detectors in explosion hazard areas.
Describes E3I040, lists applications and technical data.
Illustrates wiring principles for LON-Bus as stub line and free topology.
Identifies components and provides S3 programming for I-Bus address.
Shows terminal block and plug-in connections for the E3I040 module.
Describes E3I020 as an RS232 module and its application.
Covers wiring, technical data, and pinout connections for the E3I020 module.
Identifies key components and connection interfaces for the E3I020 module.
Describes E3H020, its application, and technical data.
Illustrates C-Bus and supply wiring principles for the E3H020.
Identifies resistors, LEDs, fuses, switches, and connectors on the E3H020 module.
Instructions for setting programming switches S1, S2, S3, and S5.
Shows terminal block connections for RS232 interfaces and system components.
Describes E3L020 and lists its technical data.
Identifies components and provides S3 programming for I-Bus address.
Shows terminal block and plug-in connections for the E3L020 module.
Describes E3L030, its application, and technical data.
Identifies components and provides S3 programming for I-Bus address.
Explains emergency operation functions for FBF, ÜE, FSD, SST, TK.
Shows terminal block and plug-in connections for the E3L030 module.
Describes E3G050 and lists its technical data.
Identifies components and provides S3 programming for I-Bus address.
Shows terminal block and plug-in connections for the E3G050 module.
Describes E3G060, its application, and technical data.
Identifies components and provides S3 programming for I-Bus address.
Instructions for setting horn modes using switches S7 and S8.
Shows terminal block and plug-in connections for the E3G060 module.
Describes E3G070 and lists its technical data.
Identifies components and provides S3 programming for I-Bus address.
Shows terminal block and plug-in connections for the E3G070 module.
Shows wiring connections for the Z3B171 relay module.
Describes B3Q700 and lists its operating voltage and current.
Discusses application, interfaces, control inputs, and operation enabled methods.
Details the mechanical design of the B3Q700, including housing and display.
Identifies components, switches, fuses, and connectors on the B3Q700.
Covers S5 programming and shows plug-in terminal connections for the B3Q700.
Details various connectors (ST1, ST2, ST3, ST4, ST7, ST8) on the B3Q700.
Describes B3R051, its application, and technical data.
Illustrates wiring principles for connecting B3R051 panels to B3Q700.
Details mechanical design and identifies components of the B3R051 panel.
Covers S1 programming and shows panel connections for the B3R051.
Describes K3R072, its application, and technical data.
Illustrates wiring and mechanical design for the K3R072 board.
Identifies components and provides S1 programming for the K3R072 board.
Shows terminal block and flat cable connections for the K3R072 board.
Describes K3G060, lists data, and illustrates wiring.
Details mechanical design and identifies components of the K3G060 card.
Shows terminal block and flat cable connections for the K3G060 card.
Describes K3I050, its application, and technical data.
Illustrates wiring and mechanical design for the K3I050 converter.
Identifies components and provides S3 programming for LON-Bus address.
Shows terminal block and connector connections for the K3I050 converter.
Describes K3I110, its application, and technical data.
Illustrates wiring and mechanical design for the K3I110 LON I/O p.c.b.
Identifies components and provides S3 programming for LON-Bus address.
Shows plug-in terminal and connector connections for the K3I110 LON I/O p.c.b.
Describes repeater panels and their typical applications.
Details mechanical design and identifies components of the repeater panels.
Covers S3 programming and explains message display formats and functions.
Lists supported character sets and local configurations for various countries.
Shows terminal block connections for the B3Q580 and B3Q590/B3Q595 panels.