Do you have a question about the Siemens HB64BC550F and is the answer not in the manual?
Ensure housing units have heat-resistant adhesive and are cut before oven installation. Remove wood chippings.
Requires ventilation opening at base. Avoid decorative panels. Position connection box in shaded area.
Maintain 20 mm gap between oven and supporting walls. Recommend 590 mm gap between shelves for ventilation.
Adhere to dimensions in figure D. Consider unit front width and handle for measurements in figure E.
Ensure house has earth connection and meets safety standards. Use approved technician. Oven is Class I.
Use H05 V V-F 3G 1.5 mm² cable. Yellow/green earth cable must be longer and connected first.
Ensure cut-off switch or accessible plug. Protect against manual contact. Cable must be long enough.
Remove door for pull-out carriage. Push oven fully in, ensuring cable is not damaged or touching hot parts.
Center and fasten with screws (4x25). Maintain top gap for ventilation. Ensure 5 mm gap from adjacent units.