Troubleshooting en
37
Fault Cause and troubleshooting
Water output is re-
duced.
Low water pressure.
Check the water pressure of the water supply sys-
tem or the external water filter system, e.g. reverse
osmosis system.
Connect the appliance only to a water connection
with sufficient water pressure. →Page9
The water filter is blocked.
Change the water filter. →Page27
Water is dripping from
the ice and water dis-
penser.
Air is in the water system.
Keep dispensing water until it contains no more air.
Ice residue is melting in the ice chute.
Remove the ice residue from the ice chute, for ex-
ample using a wooden spoon.
Ice cube production is
low.
The appliance has only recently been connected.
Wait approximately four hours until the first batch of
ice cubes is ready.
The freezer compartment has been opened frequently
or for an extended period of time.
Check ice cube production after a few hours.
Low water pressure.
Check the water pressure of the water supply sys-
tem or the external water filter system, e.g. reverse
osmosis system.
Connect the appliance only to a water connection
with sufficient water pressure. →Page9
The water filter is blocked.
Change the water filter. →Page27