EasyManua.ls Logo

Siemens LOGO! CSM 12/24 - LOGO! IP Addressing and Master Mode

Siemens LOGO! CSM 12/24
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4 Installation and Commissioning
House Control and Weather Sensors - LOGO! Set 11
Entry ID: 68585346, V2.1, 09/2018
15
Siemens AG 2018 All rights reserved
4.1.3 Assigning IP addresses to LOGO and setting the master mode
Table 4-3
No.
Action/response
LOGO! Display
1.
Go to the "Network” item via the LOGO!
display using the arrow keys C1▲ or C2▼ of
the LOGO! 8 and press OK.
2.
Select the "IP address” item.
3.
Press the OK button of the LOGO! controller
and use the arrow keys C1▲, C2▼, C3 ◄ and
C4 ► to enter your LOGO!’s IP address (here:
192.168.1.13). Confirm with the OK button.
4.
Press the ESC key to return to the previous
menu item and select "Set M/S mode”.
5.
For configuring the master LOGO!, select
"Master”.
6.
The configuration of the IP address and the
mode for the LOGO! is now complete. Press
ESC to return to the main menu
4.2 Software installation (download)
Note

Related product manuals