Technical specifications
4.2 Standards, approvals and safety notes
PROFIBUS bus connector
Equipment Manual, 02/2021, A5E50543113-AA
37
Use in industrial environments
The devices are designed for industrial use. It meets the following standards for this type of
use:
Requirements on interference emission EN 61000-6-4: 2007 + A1: 2011
Requirements on immunity EN 61000-6-2: 2005
Use in mixed areas
You can use the devices in a mixed area under certain conditions. A mixed area is used for
residential purposes and for commercial operations that do not significantly impact the
residential purpose.
If you use the devices in a mixed area, you must ensure the limits of generic standard
EN 61000-6-3 with regard to the emission of radio interference. Suitable measures for
observing these limits for use in a mixed area are, for example:
Installation of the devices in grounded control cabinets
Use of filters in the supply lines
An additional individual acceptance test is also required.
Use in residential areas
Note
The devices are not intended for use in residential areas.
If you use the devices in residential areas, radio or television reception may be affected.
Reference
The certificates for the markings and approvals can be found on the Internet under
Service&Support (http://www.siemens.com/automation/service&support).