EasyManua.ls Logo

Siemens SIPLUS CMS4000

Siemens SIPLUS CMS4000
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Operating Instructions SIPLUS CMS4000 IFN AI-D
SIPLUS CMS4000 IFN AI-D
Operating Instructions, 07/2021, A5E32612781A-AB
1
Preface 1
Product Overview 2
SIPLUS CMS4000
Installation 3
Interface Node
IFN ANALOGINPUT-DISTANCE (IFN AI-D) Wiring 4
6AT8000-1BB00-2XA0 Commissioning and Diagnosis 5
Technical Data 6
Appendix 7
Operating Instructions - English
Release 2021-07
Question and Answer IconNeed help?

Do you have a question about the Siemens SIPLUS CMS4000 and is the answer not in the manual?

Siemens SIPLUS CMS4000 Specifications

General IconGeneral
ManufacturerSiemens
ShieldingYes
Product TypeCable
SeriesSIPLUS
ModelCMS4000

Summary

Safety Guidelines

Danger

Indicates an imminently hazardous situation resulting in death or serious injury.

Warning

Indicates a potentially hazardous situation resulting in death or serious injury.

Caution

Indicates a potentially hazardous situation resulting in minor or moderate injury or property damage.

Notice

Indicates a potential situation resulting in an undesirable result or state.

Qualified Personnel

Defines personnel authorized to install and work on equipment.

Intended Use

Specifies the approved applications and connection requirements for the device.

Trademarks

Lists registered trademarks and intellectual property rights.

Disclaimer of Liability

States limitations of liability regarding document accuracy and product deviations.

1 Preface

Purpose of this Document

Explains how the operating instructions support the use of the IFN AI-D.

Required Basic Knowledge

States the necessity of basic automation technology and condition monitoring knowledge.

Validity of this Document

Confirms the document is valid for the Interface Node IFN AI-D.

Modification compared with the Previous Version

States that there are no modifications compared to the previous version.

CE Marking

Confirms the IFN AI-D meets EG-Guideline requirements for electromagnetic compatibility.

Standards

Directs users to chapter 6.1 for detailed information on standards.

Classification of Information

Advises to use additional instructions for SIPLUS CM X-Tools.

1.8 Directory

Recycling and Disposal

States the IFN AI-D is recyclable and advises on disposal methods.

2 Product Overview

What is SIPLUS CMS?

Defines SIPLUS CMS as a modular, scalable condition monitoring system for industrial plants.

2.2 What is an Interface Node IFN AI-D?

Application Area

Lists suitability for industrial environments, compact design, and ease of handling.

Display

Details the IFN AI-D's display elements, including LEDs and connectors.

2.3 Scope of Delivery

What is delivered?

Lists the items included in the package: Device IFN AI-D and Operating Instructions.

Unpacking and Checking

Provides instructions for checking the package for completeness and transport damages.

3 Installation

Installation Position, Dimensions

Describes suitability for DIN Rail or mounting angles and provides dimensions.

3.2 DIN Rail

Installation Procedure

Explains how to hang the device on the DIN rail and snap it in.

3.2.2 Disassembling

Procedure

Details steps to remove the device from the DIN rail after disconnecting cables.

3.3 Mounting Angles

Installation Procedure

Explains connecting mounting angles to the device and installing it.

Disassembling Procedure

Details steps to demount the device from its installation site.

3.4 Label Plate

Exchanging the label plate

Provides step-by-step instructions for replacing the label plate.

4 Wiring

General Rules and Regulations for operation of IFN AI-D

Covers DC 24V supply, protection against electrical influences, and grounding.

4.2 IFN AI-D

Connecting IFN AI-D to the ground (SHIELD)

Explains how to connect the device to ground using a 2.5mm² cable and M4 ring eye.

4.2.2 Connecting M12-plugs

Procedure

Details the procedure for connecting M12 connectors by pushing and twisting.

4.2.3 IEEE1394 - Connection (LNK)

Pin assignment

Explains connecting the M12 connector for IEEE1394 communication and pin assignment.

4.2.4 Power Supply Connection (PWR)

Y-Connector

Details connecting the 5-pin M12 connector for power supply and Y-connector usage.

4.2.5 Analog Input Channel

Connector assignment analog input (CH1-CH6)

Explains connecting sensors to the 5-pin M12 analog input connectors and shielding.

4.2.6 Cable Traction Relief

4.2.7 Sealing of not used round connectors

5 Commissioning and Diagnosis

Commissioning and Start-up of IFN AI-D

Outlines software requirements and steps for commissioning and start-up.

5.1.4 UIK (Unique Identification Key)

Diagnosis via LED-Indicator

Describes the meaning of different LED indicators (PWR, ERR, LNK, CH1-6) for diagnosis.

5.3 Parameterization of IFN AI-D

Diagnosis through X-Tools

Refers to the SIPLUS CMS X-Tools Reference Manual for detailed diagnosis information.

Mixed configurations with ION and IFN

Provides guidance for mixed configurations with ION and IFN devices on a bus line.

6 Technical Data

Standards and Approvals

Lists EMC directive requirements, industry standards, and conformity certificates.

Notes for the manufactures of machines

6.2 Technical Specification

Communication (LNK0...LNK2)

Details communication specifications including connectors, data protocol, and transfer rate.

Power Supply (PWR)

Provides technical specifications for the power supply connection, including voltage, current, and protection.

6.2.3 Analog Input (CH1...CH6)

Specifications at TA=25 C

Lists detailed specifications for analog inputs, including voltage, current, resistance, frequency, sampling rate, and accuracy.

6.2.4 Filter Characteristic Channel (CH1...CH6)

Exemplary filter characteristic

Displays exemplary filter characteristic curves for analog input channels.

6.2.5 Input Impedance Channel (CH1...CH6)

Functional earth (SHIELD)

Details specifications for functional earth connection, including cable, resistance, and capacitance.

Environmental conditions

Lists environmental parameters like temperature, humidity, and atmospheric pressure.

6.2.8 Construction assembly

6.2.9 Approval

7 Appendix

Order Numbers

Lists product order numbers (MLFB) for the device, accessories, and cables.

7.2 Dimensional Drawing

7.3 Service & Support in the Internet

List of Abbreviations

Defines abbreviations used throughout the document, such as AI, IFN, CMS, TIA.

Related product manuals