Siemens Micromaster Profibus User Manual

Siemens Micromaster Profibus
66 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
0,&520$67(5
352),%862SWLRQDO%RDUG
2SHUDWLQJLQVWUXFWLRQV (GLWLRQ$
8VHU'RFXPHQWDWLRQ

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Siemens Micromaster Profibus and is the answer not in the manual?

Siemens Micromaster Profibus Specifications

General IconGeneral
Product type designationMicromaster Profibus
Supported protocolsProfibus DP
Degree of protectionIP20
Baud rate9.6 kbps to 12 Mbps
Relative Humidity95% non-condensing

Summary

Definitions, Warnings, and Safety

Qualified Personnel Definition

Defines a "Qualified person" for safe operation and maintenance.

Safety Guidelines and Warning Symbols

Explains safety symbols and risk categories (DANGER, WARNING, CAUTION).

Description of the MICROMASTER PROFIBUS Optional Board

Board Functionality Overview

RS-485 Transmission System and Installation

Communication with MICROMASTER4 via PROFIBUS-DP

Cyclical Data Exchange with PROFIBUS-DP

Useful Data Structure: PPO Types

Explains PZD and PKW areas in PROFIDrive Profile data structures.

Parameter Process Data Objects (PPO)

PKW and PZD Area Functions

Explains parameter and process data areas within the telegram.

MICROMASTER4 Reaction Times

Acyclic Data Transmission

Control and Status Words

Control Word Bit Assignments

Details the bit assignments for the control word.

Status Word Bit Assignments

PKW Mechanism for Parameter Processing

Parameter Area (PKW) Structure

Explains the PKW structure for parameter read/write operations.

Parameter Identifier (PKE) and Index (IND)

Details the PKE and IND fields within the PKW.

Request and Response Identifiers

Parameter Index (IND) Structure

Subindex, PARA PAGE SEL, and Parameter Value (PWE)

Connection to PROFIBUS-DP

Installing the PROFIBUS-DP Board

Provides step-by-step instructions for mounting the board.

Connecting the Bus Cable via RS485

Bus Cable Screening and EMC Precautions

Starting Up the PROFIBUS Board

Setting the PROFIBUS Address

Explains the requirement and methods for setting the PROFIBUS address.

PROFIBUS Address Configuration Methods

Communication Board Parameter Configuration

Essential Startup Parameters (P0918, P0719)

Covers PROFIBUS address and process data master control parameters.

BICO Parameters for Setpoints and Actual Values

Process Data Monitoring

Operation with SIMATIC S7

Extended Functionality and Slave Object Manager

Internode Communication Function

Diagnostics and Troubleshooting

Diagnostics Via Alarm and Fault Numbers

Standard Diagnostics Using Parameter r2054

Parameter Accessing Error Codes (r2054.04)