EasyManua.ls Logo

Siemens SIRIUS M200D User Manual

Siemens SIRIUS M200D
234 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
GerätehandbuchManual
Industrial Controls
Load Feeders and Motor Starters
SIRIUS Motor Starter M200D PROFIBUS / PROFINET
Edition
Answers for industry.
08/2014

Table of Contents

Questions and Answers:

Siemens SIRIUS M200D Specifications

General IconGeneral
Control Voltage24 V DC
Input Voltage24 V DC
Number of Digital Outputs8
Product type designationSIRIUS M200D
Operating Temperature-25°C to +60°C
Storage Temperature-40°C to +70°C
Relative Humidity95% (non-condensing)

Summary

Product description

What are M200D distributed motor starters?

Introduces M200D motor starters, their types, and suitability for tasks.

Fieldbus interfaces

Describes PROFIBUS DP and PROFINET IO interfaces for communication.

PROFIenergy

Explains PROFIenergy for energy saving and power flow measurement.

Product family

M200D PROFIBUS/PROFINET motor starter

Details the M200D motor starter modules and available variants.

Overview of the device functions

Compares functions for electromechanical vs. electronic motor starters.

Design concept

Illustrates and labels the connections and controls on the motor starter.

Functions

Overview of the device functions

Lists device functions for electromechanical and electronic starters.

Basic functions / parameters

Explains parameters like rated operating current, load type, and voltage failure protection.

Motor control

Details functions for reversing starters, soft starters, and brake output.

Motor protection

Covers thermal motor models, trip classes, and temperature sensors.

Communication over PROFIBUS/PROFINET

Explains communication modes, commands, data plausibility, and message output.

Mounting / connection

Mounting

Provides mounting rules, derating factors, and installation procedures.

Connection

Covers required components, cables, connectors, and wiring.

Configuration / parameterization

Configuring

Explains how to configure using STEP 7, GSD files, and device names.

Parameterize

Provides an overview of device parameters and their dependencies.

Commissioning

Commissioning

Outlines the standard procedure for parameterizing and setting up the motor starter.

Requirements

Lists software and hardware requirements for commissioning.

Diagnostics

Diagnostics with LED

Explains the meaning of individual LEDs and their status combinations.

Diagnostics with STEP 7 on PROFIBUS DP

Details reading diagnostic data, evaluating interrupts, and slave diagnostics.

Troubleshooting

Covers response to faults and acknowledging faults.

Technical data

General technical specifications

Lists environmental, electrical, and mechanical specifications.

Motor starters

Provides dimensions, weight, and electrical ratings for motor starters.

Dimension drawings

Shows dimensional drawings of the motor starter module and communication modules.

Appendix

Data formats and data sets

Explains data formats, object numbers, error codes, and data set structures.

Order numbers

Lists order numbers for motor starter modules, communication modules, and accessories.

Correction sheet

Related product manuals