Mounting / connection
4.2 Connection
M200D PROFIBUS/PROFINET
104 Manual, 08/2014, A5E01577426A/RS-AA/004
Prefabricating power cables
To prefabricate power cables, you require the following:
● A crimping tool for attaching the sockets and pins on the individual wires
● For infeed on motor starters
Assignment of X1: see section Power terminal (Page 106):
– A flexible Cu cable with 4 x 2.5 mm
2
/ 4 mm
2
/ 6 mm
2
(3 wire + PE)
(for motor starters with 230 V AC brake output: 5-core cable; 3 wire + N + PE)
– Han Q4/2 socket power connector
Contact socket 2.5 mm
2
, for Han Q4/2 sockets 5 3RK1911-2BE50
Contact socket 4 mm
2
, for Han Q4/2 sockets 5 3RK1911-2BE10
Contact socket 6 mm
2
, for Han Q4/2 sockets 5 3RK1911-2BE30
Crimping tool 4 / 6 mm² 1 3RK1902-0CW00
Consumer connection on the motor starter
For the assignment of X2, see Power terminal (Page 106):
● A flexible Cu cable with 1.5 mm
2
or 2.5 mm
2
– Without brake control: 3 wire + PE
– With brake control: 5 wire + PE
– With temperature sensor: 2 additional wires
– Han Q8/0 pin power connector
Connector set, 8 X 1.5 mm
2
, 9 pin, complete with PG16 cable entry 3RK1902-0CE00
Connector set, 8 X 2.5 mm
2