Technical data
8.2 Motor starters
M200D PROFIBUS/PROFINET
170 Manual, 08/2014, A5E01577426A/RS-AA/004
Note
This product is designed for environment A (industrial environments). In household
environments, this device can cause unwanted radio interference. The user may be required
to implement appropriate measures in this case.
8.2
Motor starters
Motor starter version
PROFIBUS/PROFINET
DSte / RSte
sDSSte/sRSSte
Mounting dimensions Width
Height
Depth
294 mm
215 mm
162 mm
Weight 2820 g / 3080 g 3160 g / 3360 g
Control circuit
Operating voltage U
DC24V-NS
20.4 to 28.8 V DC
Current consumption from U
DC24V-NS
without sensors connected
with sensors connected
max. 100 mA
max. 300 mA
(total sensor current consumption < 200 mA)
Operating voltage U
DC24V-S
20.4 to 28.8 V DC
Current consumption from U
DC24V-S
< 100 mA
Main circuit
Max. power of three-phase motors at 400 V 5.5 kW
Rated operating current
AC 1/2/3 At 400 V
At 500 V
12 A
9 A
AC-4 At 400 V 4 A
AC-53a (8h operation) At 400 V 12 A (soft start)
9 A (direct start)
Rated operating voltage
Certification to EN 60947-1 Appendix N
Certification to UL508 and CSA C22.2 No. 14
400 V AC, 50 / 60 Hz
600 V AC, 50 / 60 Hz
400 V AC, 50 / 60 Hz
480 V AC, 50 / 60 Hz
Product category according to UL NLDX NMFT