EasyManua.ls Logo

Siemens PROFINET SIRIUS 3RW5 User Manual

Siemens PROFINET SIRIUS 3RW5
214 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Industrial Controls
Soft starters and solid-state
switching devices
SIRIUS 3RW5 PROFINET
communication modules
Equipment Manual
05/2021
A5E35631297002A/RS-AD/004
Siemens Industry Online
Support
1
Safety notes
2
Description
3
Mounting and dismantling
4
Connection
5
Con󹪝guring
6
Messages and diagnostics
7
Functions
8
Maintenance and service
9
Technical data
10
Dimension drawings
11
Circuit diagrams
12
Appendix
A

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Siemens PROFINET SIRIUS 3RW5 and is the answer not in the manual?

Siemens PROFINET SIRIUS 3RW5 Specifications

General IconGeneral
BrandSiemens
ModelPROFINET SIRIUS 3RW5
CategoryController
LanguageEnglish

Summary

Siemens Industry Online Support

Support Request

Online form to send questions directly to technical support.

Additional documentation

Links to further manuals and online helps for automation systems.

mySupport

Personal work area for managing requests, filters, favorites, notifications, products, and documentation.

Safety notes

Security information

Information on industrial security functions for secure operation of plants, systems, machines and networks.

Data security in automation

Requirements, threats, and precautions for data security in industrial environments.

ESD Guidelines

Guidelines for handling electrostatic sensitive components and devices to prevent damage.

Electromagnetic compatibility (EMC) according to IEC 60947-4-1

Information on EMC design and potential radio interference in domestic environments.

Recycling and disposal

Guidance on environmentally friendly recycling and disposal of old electrical and electronic devices.

Description

History

Overview of manual revisions and new features released across different versions.

Hardware configuration

Details on the article numbers and hardware layout of the 3RW5 PROFINET communication modules.

Functions of the 3RW5 PROFINET communication module

Overview of PROFINET IO characteristics and supported functions for the communication module.

Access options for the 3RW5 soft starters

Details on how to access the soft starters via different paths like PROFINET, web client, or HMI.

Operating modes and master control function

Explanation of different operating modes and how master control is managed between sources.

Mounting and dismantling

Installing the 3RW5 communication module in the 3RW5 soft starter

Step-by-step guide for mounting the communication module into the soft starter's slot.

Break out the cover of the slot

Procedure for safely removing the slot cover from the soft starter before module installation.

Mount the 3RW5 communication module in the slot of the 3RW5 Soft Starter

Instructions for physically installing the communication module into the prepared slot.

Removing the 3RW5 communication module from the 3RW5 soft starter

Procedure for safely removing the communication module from its slot in the soft starter.

Installing the 3RW5 communication module on a level surface

Instructions for mounting the communication module directly onto a flat surface.

Removing the 3RW5 communication module from a level surface

Procedure for safely removing the communication module that is mounted on a level surface.

Connection

COM connecting cable

Information about the COM connecting cable used for communication between devices.

Connecting the COM connecting cable to the 3RW50 soft starter

Step-by-step instructions for connecting the COM cable to the 3RW50 soft starter.

Connecting the COM connecting cable to the 3RW5 communication module

Guide for connecting the COM connecting cable to the communication module.

Removing the COM connecting cable on the 3RW5 communication module

Procedure for disconnecting the COM connecting cable from the communication module.

Remove the COM connecting cable on the 3RW50 soft starter

Instructions for disconnecting the COM connecting cable from the 3RW50 soft starter.

Fieldbus

Details on connecting to the fieldbus for industrial communication.

Connecting the bus connector

Procedure for connecting the fieldbus connector to the communication module.

Configuring

Configuring the 3RW5 Soft Starter in the PROFINET IO system

Steps for configuring the 3RW5 Soft Starter within a PROFINET IO system.

Configuring the 3RW5 Soft Starter

General procedures for configuring the 3RW5 Soft Starter, including via HMI or without.

Configuring 3RW5 soft starters without assistance from a 3RW5 HMI High Feature

Configuration steps via controller software without using a 3RW5 HMI High Feature.

Device name

Information on selecting and setting the device name for PROFINET communication.

IP parameters

Details on setting IP addresses, subnet masks, and router addresses for PROFINET devices.

Integrating the 3RW5 Soft Starter into PROFINET IO system

Methods for integrating the soft starter into the PROFINET IO system using HSP or GSDML files.

Operation on failure of the bus connection to the controller

Defines behavior of the soft starter upon bus connection failure or CPU stop in 'Automatic' mode.

Messages and diagnostics

LED display

Explanation of the diagnostic LEDs on the 3RW5 PROFINET communication modules.

Diagnostics via configuration software of the controller

How the controller software provides diagnostics and handles interrupts from the soft starter.

Diagnostics via data sets

Information on using data sets for diagnostics, including communication module, soft starter, and HMI diagnostics.

Error codes for negative data set acknowledgement

List and causes of error codes received for negative data set acknowledgements.

Disable or enable group error and group warning

Configuration options to enable or disable the transmission of error and maintenance interrupts.

Errors and remedial measures on the 3RW5 communication module

Table of possible errors and their remedies for the communication module.

Messages about the mode

Description of message bits in data set 92 indicating which control source has priority.

Functions

PROFIenergy

Vendor-neutral profile for energy management, supporting commands for energy saving and measured values.

NTP (time synchronization)

Procedure for synchronizing the real-time clock using the Network Time Protocol.

Web server

Functionality to retrieve information and control soft starters via web pages using a web browser.

OPC UA server

Details on using the OPC UA server for data exchange between clients and systems.

Operation without PN control

Parameter determining soft starter behavior relative to a PLC, relevant for web server or OPC UA server use.

System redundancy S2

Enables setup of system-redundant plants for high availability automation systems.

Dynamic Reconfiguration (DR)

Ability to make system changes without restarting devices or controllers, also known as Configuration in Run (CiR).

Maintenance and service

Firmware update

Instructions and information on updating the firmware to extend functions and improve security.

Performing firmware update with micro SD card (3RW5 HMI High Feature)

Step-by-step guide for updating firmware using a micro SD card via the 3RW5 HMI High Feature.

Replacing the 3RW5 communication module

Procedure for replacing the communication module, noting that communication parameters are not automatically transferred.

Restoring factory settings

How to reset the soft starter, communication module, and HMI to their factory default settings.

Technical data

Technical data in Siemens Industry Online Support

Information on how to find technical data sheets and overview tables on the Siemens Industry Online Support portal.

Dimension drawings

CAx data

Information on accessing CAx data (CAD drawings, etc.) for devices via Siemens Industry Online Support.

Drilling patterns for 3RW5 communication module on the 3RW50 soft starter

Detailed drilling patterns for mounting the 3RW5 communication module on 3RW50 soft starter sizes S6 and S12.

Circuit diagrams

CAx data

Information on accessing CAx data, which includes circuit diagrams, via Siemens Industry Online Support.

Appendix

Content of the appendix

Overview of the appendix structure and content, referencing Equipment Manuals for more details.

Data formats

Explanation of data formats, including current values as percentages and bit arrangements.

Statistic data

Description of statistic data grouping operating states for load relevance and preventive diagnostics.

Maximum pointer

Information on stored extreme measured values used for preventive diagnostics, which can be deleted.

Process data and process images

Details on how the 3RW5 soft starter's functions are controlled and monitored via process data and images.

Data sets

Comprehensive list of available data sets for communication module, soft starter, HMI, and I&M data.

Related product manuals