Siemens PROFINET SIRIUS 3RW5 - Data Set 134: Parameter Maintenance

Siemens PROFINET SIRIUS 3RW5
214 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Object
No.
Byte Bit Data format Parameters Value range
[encoding]
Incre‐
ment
3RW
50 /
52
1)
[D
3)
]
55 /
55‑F
2)
[D
3)
]
2223 42 0 Unsigned16 Analog output - meas‐
ured value
[0 ...632] - - r/w
[0]
[0] Deactivated
[502] Motor temperature rise
[504] Phase current I L1 (%)
[505] Phase current I L2 (%)
[506] Phase current I L3 (%)
[510] Line voltage U L1-L2
(rms)
[511] Line voltage U L2-L3
(rms)
[512] Line voltage U L3-L1
(rms)
[513] Phase current I L1 (rms)
[514] Phase current I L2 (rms)
[515] Phase current I L3 (rms)
[518] Switching element heat‐
ing
[521] Active power
[523] Power factor L1...3
[528] Phase current average
(%)
[530] Phase current average
(rms)
[632] Active energy import to‐
tal
2224 46 0 Unsigned32 Analog output - range
start value
0 … 4 294 967 294
[0 … 4 294 967 294]
1 r/w
[0]
r/w
[0]
2225 50 0 Unsigned32 Analog output - range
end value
0 … 4 294 967 295
[0 … 4 294 967 295]
1 r/w
[96]
r/w
[27 648
]
- 54 ...
199
- - Reserved - - - -
1)
Supported by SIRIUS 3RW50 and 3RW52 soft starters
2)
Supported by SIRIUS 3RW55 and 3RW55 Failsafe soft starters
3)
Default encoding
A.4.5.10 Data set 134: Parameter Maintenance
Read (r) and write (w) access to the parameter Maintenance is possible. Data set 134 is not
supported by the 3RW50 and 3RW52 soft starters.
Byte Data format Meaning 3RW55 /
55‑F
1)
0 Unsigned8 Coordination
[0x21] Write via acyclic bus channel – user program
x
2 Unsigned8 Slot number x
Appendix
A.4 Data sets
SIRIUS 3RW5 PROFINET communication modules
Equipment Manual, 05/2021, A5E35631297002A/RS-AD/004 193