EasyManua.ls Logo

Siemens PROFINET SIRIUS 3RW5 - Dynamic Reconfiguration (DR)

Siemens PROFINET SIRIUS 3RW5
214 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8.7 Dynamic Recon󹪝guration (DR)
Requirement
3RW5 PROFINET High Feature communication module with 󹪝rmware V3.0 or higher
Changes during operation
Changes during operation (Dynamic Recon󹪝guration) refer to the property, based on redundant
communication connections, of being able to make changes to the system without having to
restart devices or controllers and without a󹪜ecting communication in the network. This applies
to measures on or with compact devices as well as to modular devices or proxies.
Examples include changing a device con󹪝guration, replacing a device, adding or repairing
components, or changing parameters.
Formerly this function was called Con󹪝guration in Run (CiR).
Functions
8.7 Dynamic Recon󹪝guration (DR)
SIRIUS 3RW5 PROFINET communication modules
Equipment Manual, 05/2021, A5E35631297002A/RS-AD/004 137