Functions
3.4 Fieldbus interface
M200D PROFIBUS/PROFINET
Manual, 08/2014, A5E01577426A/RS-AA/004
31
Response to CPU/master STOP
This device parameter enables you to specify how the motor starter is to behave in the event
of a CPU/Master stop:
● Retain last value
● Switch substitute value
This is only relevant in "automatic" mode.
In the event of a bus failure, the outputs of the motor starters are controlled by a
corresponding substitute process image.
This device parameter is only relevant if you have parameterized "response to CPU/master
STOP" as "switch substitute value".
Motor CW and motor CCW cannot be set simultaneously.
The substitute value can be switched individually for the following parameters:
● Motor CW
● Motor CCW (on reversing starters only)
● Brake control (only on motor starters with brake output)
● Trip reset
● Emergency start
● Self-test
● Output 1
● Output 2
● Disable quick stop