The following I&M (identification & maintenance function) data is supported by all M200D
PROFIBUS/PROFINET motor starters:
I&M 0 Device identification As stored in the device initialization
I&M 1 Equipment designation Entered by the user during configuration via the Device
Properties screen form in HW Config
I&M 2 Installation
I&M 3 Description
With PROFINET, the I&M data can be accessed via data sets 0xAFF0 - 0xAFF3 (PNO).
DS231 Read device identification
PROFIBUS: I&M 0
The following data is saved in data set DS 231:
0 ... 9 0x00 Reserved = 0 —
10 ... 11 0x002A MANUFACTURER_ID 42 = Manufacturer ID SIEMENS
12 ... 31 (20 bytes) ORDER_ID Order No. (MLFB)
32 ... 47 (16 bytes) SERIAL_NUMBER Serial number
48 ... 49 (2 bytes) HARDWARE REVISION Hardware revision or product version
50 ... 53 (4 bytes) SOFTWARE_REVISION Firmware version
54 ... 55 (2 bytes) REV_COUNTER Provides information about the parameterized
changes on the module. The "REV_
COUNTER" is incremented after each
change.
56 ... 57 (2 bytes) PROFILE_ID Gives information about the PROFIBUS
profile supported by the device and the line of
products belonging to the device.
58 ... 59 (2 bytes) PROFILE_SPECIFIC_TYPE Used to supplement the object "PROFILE_ID"
and contains further information on the
profile.
60 ... 61 (2 bytes) IM_VERSION Provides information about the version of the
identification data (01 01hex = Version 1.1).
62 ... 63 (2 bytes) IM_SUPPORTED Provides information about the available
identification data (Index 2 to 4).