PROFIBUS Optional Board Operating instructions
6SE6400-5AK00-0BP0
37
6WDUWLQJXSWKH352),%86%RDUG
127(
Before the converter with connected PROFIBUS board is switched on, you should
plug either the standard display panel (SDP), a basic operator panel (BOP) or an
‘Advanced Operator Panel’ (AOP) into the PROFIBUS board.
The PROFIBUS optional board may only be installed when the converter power
supply is disconnected.
352),%86DGGUHVV
A minimum requirement for starting up the PROFIBUS optional board is the
PROFIBUS address setting.
Two methods of setting the PROFIBUS address:
½ Via the seven DIP switches on the communication board or
½ via parameter "P0918".
',3VZLWFKHV
1 PROFIBUS address switch (DIP switch)
2 (for Siemens internal use only)
Fig. 5-1 View of DIP switch