INTRODUCTION The Model RNI from Siemens Industry, Inc., allows for
the remote installation of the PMI/PMI-2/PMI-3, Global
PMI/PMI-2/PMI-3 (on XNET), SSD-C-REM (on HNET),
and the LVM/LCM-8/SCM-8/FCM-6/SIM-16/OCM-16
(on CAN) modules. When used in a REMBOX4, the
FMT and LVM are also supported.
The HNET/XNET can be wired either Style 4 or Style
7. The RNI must be placed in between two NIC-Cs
when used in a Style 7 Network with the Global PMI/
PMI-2/PMI-3 (on XNET) or the SSD-C-REM (HNET).
When using the PMI/PMI-2/PMI-3, the RNI may be
located in the middle or at the end of the HNET. Refer
to the table below for the allowable locations of
modules at the end of a HNET or XNET.
afodnEehttatnemecalPeludoM
krowteNTENXroTENH
TENHTENX
4elytS7elytS4elytS7elytS
MER-C-DSSYN**
3-IMP/2-IMP/IMP
)TENH(
YY* *
-IMP/IMPLABOLG
)TENX(3-IMP/2
**YN
krowtensihtnodewollatoN*,dewollA=Y,dewollatoN=N
The CAN network may only be wired Style 4. The RNI may be located at the end or in
the middle of a CAN network. A 24VDC input is also required. This can be obtained
from the PSC-12 power limited output (TB3) or any 24 VDC UL/ULC regulated, power
limited power supply listed for fire protective signaling use. Audio signals for the LVM
and FMT are connected to TB1 of the PSC-12.
The RNI mounts in the rear of either the REMBOX2 or REMBOX4 enclosures. It can
also be installed in a CAB1, CAB2, or CAB3 using the mounting plate RNI-CAB-BRKT.
The RNI provides terminal blocks for all field wiring connections. Internal connections
are made to plug in connectors specifically provided for each of the installed modules.
The HNET/XNET and the CAN networks can be used simultaneously.
Remote Network Interface
Installation Instructions
Model RNI
X
H
24 V
TB1
1
2
9
10
P1
1
4
3
6
4
1
3
6
P3
P4
TB2
RNI
TB3
TB4
TB5
TB6
2
1
JP1
P6
S1
P5
P7
OFF
ON
1
2
7
8
P2
Figure 1
RNI Remote Network
Interface
Question and Answer IconNeed help?

Do you have a question about the Siemens RNI and is the answer not in the manual?

Siemens RNI Specifications

General IconGeneral
BrandSiemens
ModelRNI
CategoryRecording Equipment
LanguageEnglish

Summary

Introduction to Model RNI

Pre-Installation Steps

Installation Procedure

Post-Installation Checks

24VDC Power Input Verification

Confirm 24VDC power input on TB1 is connected and polarity is correct.

S1 Network Termination Setting

Check S1 setting for HNET/XNET end or middle placement.

P5 Network Selection

Verify P5 is set to H for HNET or X for XNET.

CAN Network Termination

Check CAN termination if RNI is at the end of the network.

P7 Audible Indicator Setting

Set P7 to ON for local sound, OFF otherwise.

RNI Compatibility

Electrical Ratings

Cyber Security Disclaimer

Related product manuals