Technical Specifications
5.2Failsafe Alarm Relay Specifications
5.2 Failsafe Alarm Relay Specifications
Hazardous Environments
Maximum Switching Voltage Rated
Switching
Current
Isolation
30 VDC 1 A
80 VDC
30 VAC
0.3 A
1500 V
rms
for 1 minute
Non-Hazardous Environment
Maximum Switching Voltage Rated
Switching
Current
Isolation
30 VDC 2 A, 60 W
125 VDC 0.24 A, 30 W
125 VAC 0.5 A, 62.5 W
220 VDC 0.24 A, 60 W
250 VAC 0.25 A, 62.5 W
1500 V
rms
for 1 minute
5.3 Supported Networking Standards
The following networking standards are supported by RUGGEDCOM RS910:
Standard 10 Mbps
Ports
100 Mbps
Ports
1000 Mbps Ports Notes
IEEE 802.3x • • • Full Duplex Operation
IEEE 802.3z • 1000Base-LX
IEEE 802.3ab • 1000Base-Tx
IEEE 802.1D • • • MAC Bridges
IEEE 802.1Q • • • VLAN (Virtual LAN)
IEEE 802.1p • • • Priority Levels
5.4 Copper Ethernet Port Specifications
The following details the specifications for copper Ethernet ports that can be ordered
with the RUGGEDCOM RS910.
Speed
a
Connector Duplex
a
Cable Type
b
Wiring
Standard
c
Maximum
Distance
d
Isolation
e
10/100Base-
TX
DB9 FDX/HDX > CAT 5 TIA/EIA
T568A/B
100 m
(328 ft)
1.5 kV
30
RUGGEDCOM RS910
Installation Manual, 04/2021, C79000-G8976-1029-12