Chapter 4
Technical Specifications
RUGGEDCOM RSG2100
Installation Guide
30 Failsafe Relay Specifications
Non-Hazardous Environments
Input Range
Power Supply Type
Minimum Maximum
Internal Fuse Rating
e
f
Maximum Power
Consumption
g
24 VDC 10 VDC 36 VDC 6.3 A(F)
48 VDC 36 VDC 72 VDC 3.15 A(T)
HI (125/250 VDC)
h
88 VDC 300 VDC 2 A(T)
HI (110/230 VAC)
h
85 VAC 264 VAC 2 A(T)
28 W
e
(F) denotes fast-acting fuse
f
(T) denotes time-delay fuse.
g
Power consumption varies based on configuration. 10/100Base-TX ports consume roughly 1 W less than fiber optic ports.
h
The HI power supply is the same power supply for both AC and DC.
Section4.2
Failsafe Relay Specifications
Parameter Value (Resistive Load)
Max Switching Voltage 240 VAC, 125 VDC
Rated Switching Current 2 A @ 240 VAC, 0.15 A @ 125 VDC, 2 A @ 30 VDC
Maximum Switching Capacity 150 W, 500 VA
Section4.3
Supported Networking Standards
Standard 10 Mbps Ports 100 Mbps Ports 1000 Mbps Ports Description
IEEE 802.3
ü
10BaseT/10BaseFL
IEEE 802.3u
ü
100BaseTX/100BaseFX
IEEE 802.3x
ü ü ü
Flow Control
IEEE 802.3z
ü
1000BaseLX
IEEE 802.3ab
ü
1000BaseTx
IEEE 802.3ad
ü
Link Aggregation
IEEE 802.1D
ü ü ü
MAC Bridges
IEEE 802.1D
ü ü ü
Spanning Tree Protocol (STP)
IEEE 802.1p
ü ü ü
Class of Service (CoS)
IEEE 802.1Q
ü ü ü
VLAN (Virtual LAN) Tagging
IEEE 802.1w
ü ü ü
Rapid Spanning Tree Protocol (RSTP)