EMC and Environmental Type Tests 43
• IEC 61850-3
Communication Networks and Systems in Substations – Part 3: General Requirements
• EN 50121-4
Railway Applications – Electromagnetic Compatibility – Emission and Immunity of the Signaling and
Telecommunications Apparatus
Section6.2
EMC and Environmental Type Tests
The RUGGEDCOM RSG2100 has passed the following Electromagnetic Compatibility (EMC) and environmental
tests.
EMC Type Tests per IEC 61850-3
NOTE
• In the case of an all fiber port configuration, this product meets all Class 2 requirements. Otherwise,
all Class 1 requirements are met for copper ports.
• If the unit contains copper ports, the IEC 1613 conformance is Class 1, during which disturbance
errors may occur but recovery is automatic.
• If the unit contains all fiber ports, the IEC 1613 conformance is Class 2, during which no disturbance
errors will occur.
Test Description Test Levels Severity Levels
Enclosure Contact ±8 kVIEC 61000-4-2 ESD
Enclosure Air ±15 kV
4
IEC 61000-4-3 Radiated RFI Enclosure Ports 20 V/m Note
a
Signal Ports ±4 kV @ 2.5 kHz Note
a
DC Power Ports
AC Power Ports
IEC 61000-4-4 Burst (Fast Transient)
Earth Ground Ports
±4 kV 4
Signal Ports ±4 kV Line-to-Ground,
±2 kV Line-to-Line
4
DC Power Ports ±2 kV Line-to-Ground,
±1 kV Line-to-Line
3
IEC 61000-4-5 Surge
AC Power Ports ±4 kV Line-to-Ground,
±2 kV Line-to-Line
4
Signal Ports
DC Power Ports
AC Power Ports
IEC 61000-4-6 Induced (Conducted) RFI
Earth Ground Ports
10 V 3