Communication Ports
4.1Redundant Network Access (RNA) Ports
4.1 Redundant Network Access (RNA) Ports
The RUGGEDCOM RSG907R features three dedicated Small Form-factor Pluggable
(SFP) transceiver sockets for PRP/HSR applications:
HSR/PRP Ports
Port Description
A
B
Port A and B enable the device to connect to
a Parallel Redundancy Protocol (PRP) network
or a High-Availability Seamless Redundancy
(HSR) ring.
5 The Coupler port serves the following
purposes:
To connect two HSR devices to form a
QuadBox
To connect a SAN (Singly Attached Node)
to an HSR ring via an HSR device
To connect a VDAN (Virtual Dual Attached
Node) to a PRP network via a PRP device
To connect an HSR ring to a PRP network
and vice versa
To connect an HSR ring to an RSTP
network
1
2
1
Ports A and B
2
Port 5 (Coupler)
Figure4.2 HSR/PRP Ports
LEDs
Each RNA port features an LED that indicates the link/activity state of the port.
State Description
Green (Solid) Link established
Green (Blinking) Link activity
Off No link detected
Compatible SFPs
For more information about which SFP transceivers are compatible with the
RUGGEDCOM RSG907R, as well as instructions for ordering and installation/
removal, refer to the RUGGEDCOM SFP Transceiver Catalog [https://
support.industry.siemens.com/cs/ca/en/view/109482309].
IMPORTANT
Only use SFP transceivers approved by Siemens for RUGGEDCOM products. Siemens
accepts no liability as a result of performance issues related in whole or in part to
third-party components.