Technical Specifications
5.4Copper Ethernet Port Specifications
Standard 10 Mbps
Ports
100 Mbps
Ports
1000 Mbps Ports Notes
IEEE 802.3u 100Base-TX/100Base-FX
IEEE
1588-2008
Precision Time Control
(PTP) Version 2
IEC
62439-2:2016
Media Redundancy
Protocol (MRP)
IEC
62439-3:2016
High-Availability Seamless
Redundancy (HSR), Parallel
Redundancy Protocol (PRP)
5.4 Copper Ethernet Port Specifications
The following details the specifications for copper Ethernet ports that can be ordered
with the RUGGEDCOM RSG909R.
Speed
a
10/100/1000Base-TX
Connector RJ45
Duplex
a
FDX/HDX
Cable Type
b
> CAT 5
Wiring Standard
c
TIA/EIA T568A/B
Maximum Distance
d
100 m (328 ft)
Isolation
e
1.5 kV
a
Auto-negotiating.
b
Shielded.
c
Auto-crossover and auto-polarity.
d
Typical distance. Dependent on the number of connectors and splices.
e
RMS 1 minute.
5.5 Operating Environment
The RUGGEDCOM RSG909R is rated to operate under the following environmental
conditions.
Ambient Operating
Temperature
ab
-40 to 85 °C (-40 to 185 °F)
Ambient Storage Temperature -40 to 85 °C (-40 to 185 °F)
Ambient Relative Humidity
c
5% to 95%
Maximum Altitude 2000 m (6562 ft)
a
Measured from a 30 cm (12 in) radius surrounding the center of the enclosure.
b
Operating temperature may vary based on the limitations of installed SFPs. Refer to the RUGGEDCOM
SFP Transceivers Catalog for SFP temperature ratings.
c
Non-condensing.
RUGGEDCOM RSG909R
Installation Manual, 04/2021, C79000-G8976-1388-13
33