SCALANCE S
Commissioning and Hardware Installation Manual, 05/2016, C79000-G8976-C266-06
11
Attachment of end devices or network components over twisted
pair
10/100/1000 Mbps (half/full duplex)
2 x RJ-45 jacks with MDI-X assignment
3 x RJ-45 jacks with MDI-X assignment
SCALANCE S627-2M 3 x RJ-45 jacks with MDI-X assignment
2 x media modules slots each for one 2-port media
Connector for power supply
1x4-pin plug-in terminal block
Connector for signaling contact
1x2-pin plug-in terminal block
Power supply Supply 24 VDC (19.2 to 28.8 VDC)
• Implemented redundantly
• Safety extra-low voltage (SELV)
Typical power consumption at 24 VDC, 1000 Mbps
SCALANCE S627-2M 12.0 W without media modules / max. 2.5 W extra per
Max. current consumption at rated voltage
Connection over Industrial Ethernet FC TP cables
0 - 100 m Industrial Ethernet FC TP standard cable with
IE FC RJ-45 plug 180
or
Over Industrial Ethernet FC outlet RJ-45 with 0 - 90 m
Industrial Ethernet FC TP standard cable + 10 m
0 - 85 m Industrial Ethernet FC TP marine/trailing cable with
IE FC RJ-45 plug 180
or
0 - 75 m Industri-
al Ethernet FC TP marine/trailing cable + 10 m
TP cord